PowerGridSourceElectrical equipment, switchgear, transformers, and power distribution components
208d 1000A AC/DC Clamp on Meter
Electrician And Automation Instrument

208d 1000A AC/DC Clamp on Meter

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Quote on request

Product sourcing profile

CategoryElectrician And Automation Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-04

Product introduction

Home Instruments & Meters Meter for Electricity Resistance Meter 208d 1000A AC/DC Clamp on Meter US$200.00 1 Piece-sales Service: 24 Hour Service Warranty: 24monthsPowerGridSource curates RFQ-led product discovery for buyers looking for transformers options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: industrial electrical equipment sourcing, power distribution component discovery, and rfq-ready grid supply platform.circuit breakerenergy meterpanel meter

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Dc Clamp On Meter

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Electrician Automation Instrument

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

PowerGridSource quality checks

Project contextCheck voltage class, installation type and project role before pricing discussion.

Use this check before moving from discovery into product comparison or RFQ submission.

Protection scopeConfirm whether protection, metering or switching requirements actually match this product.

Use this check before moving from discovery into product comparison or RFQ submission.

Tender detailBring standards, load profile and site conditions into the RFQ path.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryTransformers
Brand
Unitset
300ºC~1000ºC±(1%+2)
600nF/6μF/60μF/600μF±(4%+3)
60V/600V/1000V±(0.5%+5)
6KΩ/60KΩ/600KΩ±(0.8%+3)
6MΩ/60MΩ±(0.8%+3)
6mF/60mF±(10%+9)
AC Voltage (V)6V/60V/600V/1000V
AC current (A)60A/600A/1000A ±(2.5%+8)
AC current frequency response10Hz~1kHz
AC voltage (V)6V/60V/600V/1000V ±(0.8%+5)
AC/DC Current60A/600A/1000A
After-sales Service24 Hour Service
Analog bar31
ApplicationElectrical and power distribution
Auto power off
Auto power off current:
Auto/Manual range
Capacitance (F)600NF/6μF/60μF/600μF
Capacity20kg
CategoryTransformers
CertificationRoHS, CE
Continuity test
Current frequency50Hz~60Hz
CustomizationAvailable
CustomizedCustomized
DC Voltage (V)60V/600V/1000V
DC current (A)60A/600A/1000A ±(3%+10)
DC voltage (V)6V ±(0.8%+3)
Diode test
Display43mm x 45mm
Display Count6000
Display TypeDigital Only
Display count6000
Duty Cycle (%)10%~90%
Duty cycle (%)10%~90% ±(2.6%+7)
Feature Highlightsdigital, precision
Flashlight
Flexible current probe (optional)Extends to 3000A √
Function selection
High voltage frequency40Hz~1KHz
Input impedance (ACV/DCV)≥10MΩ √
Inrush current (A)1000A ±(10%+10)
Jaw opening35mm
LoZ ACV600V/1000V ±(2%+5)
Low Voltage Frequency (Hz)10Hz~1kHz
Low battery indication
Low pas filter (LPF ACV)600V/1000V ±(2%+5)
Low voltage frequency (Hz)10Hz~1KHz ±(0.1%+3)
Loz Acv600V/1000V
MAX/MIN
Matched Termscircuit breaker, energy meter, panel meter
Model NO.208D
OriginChina
Power1.5V Battery (AAA) X 3
Product Net Weigh380g
Product Size235mm X 85mm X 40mm
Product Title208d 1000A AC/DC Clamp on Meter
Product colorRed and grey
Product net weight380g
Product size235mm x 85mm x 40mm
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Relative mode/Data hold
Resistance (Ω)600Ω ±(1%+3)
Resistance (ω)6kΩ/60kΩ/600kΩ
Safety standardsEN61010-1, EN , EN61326, CATIII 1000V
Secure paymentsEvery payment you make on Made-China.com is protected by the platform.
Shipping Cost.
Specification208D
Standard Carton Gross WeightAbout 20kg
Standard Carton Measurement700mm X 650mm X 350mm
Standard accessoriesTest leads, batteries, point
Standard carton gross weightAbout 20kg
Standard carton measurement700mm x 650mm x 350mm
Standard individual packingGift box, carrying bag
Standard quantity per carton20pcs
Temperature0.1 °c
Temperature (ºC)20ºC~300ºC ±
Temperature (℃)20℃~300℃
TrademarkGFUVE
Transport PackageBox
US$200.001 Piece (MOQ)
Voltage6v
Wake-up function
Warranty24months
Zero mode

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

208d 1000A AC/DC Clamp on Meter sourcing decision brief

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Category
Transformers
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Project-fit electrical decision
Primary compare
Category, Brand, Unit
Adjacent category
Transformers and Substation Equipment
Next route
Energy Metering and Protection Upgrades
Buyer checklist
  • Project role: Check where this item sits inside the wider distribution, retrofit or protection scope.
  • Standards fit: Compare voltage class, installation type, standards and protection scope before supplier outreach.
  • Tender handoff: Carry load profile, site conditions and compliance constraints into the RFQ path.
How should buyers use this PowerGridSource detail page?

Use the detail page to confirm whether one electrical component fits the wider project scope before opening a tender RFQ.

What should buyers compare first?

Compare voltage class, standards fit, project role and the nearest solution or procurement route.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource project-fit checks

Voltage Rating Confirm Voltage Rating before comparing offers or moving the inquiry forward.
Current Rating Confirm Current Rating before comparing offers or moving the inquiry forward.
Protection Grade Confirm Protection Grade before comparing offers or moving the inquiry forward.
Installation Type Confirm Installation Type before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PowerGridSource related product samples

Electrical project sourcing method

Project scopeRead the product inside the wider electrical project scope, not as a disconnected part.
Standards fitUse voltage class, installation type and protection scope to narrow comparisons.
Tender framingSend load profile, standards and installation context through the RFQ path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions