CAREPOLE | RFQ Sourcing Details
Lightning Arresters · Quote on request
This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.
Product specs
Buyer's Digest
Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Lightning Arresters. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.
Original product description
CAREPOLE: dry-type pole-mounted transformers The pole-mounted dry-type CAREPOLE turns power distribution systems into safer, more environmentally friendly grids.
Optimally protected by its cast-resin enclosure against normal and harsh environmental conditions, this maintenance-free transformer enables reliable operation while reducing total costs of ownership.
The eco-friendly alternative for safer and more reliable distribution grids , innovative dry-type transformer, CAREPOLE was selected for 2022 EUISSCA Sustainable Supply Chain Award! CAREPOLE is an eco-friendly alternative for safer and more reliable distribution grids.
Our environmentally friendly CAREPOLE is setting new standards Are you in need of a reliable, digital (Sensformer), eco-friendly and durable cast-resin transformer? We have an answer for you: CAREPOLE.
Reliability Sustainability Digitalization Easy handling CAREPOLE was developed by Siemens Energy for your overhead distribution line networks. CAREPOLE answers the challenges which transformers can possibly meet.
Its windings are sealed with cast resin under vacuum, separated from the core, and the insulation is solid and resist the dielectric loads in the distribution network. The cast resin also protects your unit against severe weather conditions. High- and low-voltage bushings are cast in one piece with the windings.
This technical design makes CAREPOLE especially reliable and unsusceptible to failures. Do you need an off-load tap changer? We can provide one near one of the top high-voltage bushings. It is set via a patented tap panel when the transformer is de-energized.
Weatherproof design Your CAREPOLE withstands any weather conditions and ensures a reliable operation. The winding surfaces and core are in direct , resulting in efficient natural heat exchange.
The frame surrounding the core creates a solid mechanical structure that protects the unit against corrosion and direct sunlight. The frame also serves as a lifting and fastening mechanism for the transformer. A special manufacturing process and advanced sealing compound ensure lownoise operation and perfect .
The core is wound from highquality electrical steel. The solid insulation of CAREPOLE is stable under all weather conditions and prevents moisture from penetrating the windings and core.
Overload and short circuit capability CAREPOLE can withstand higher temperatures than liquid-filled transformers, due to the solid insulation. Accordingly, CAREPOLE units can be overloaded for longer periods of peak demand and can better withstand short-circuit effects.
One key factor of the energy market is sustainability. CAREPOLE makes power distribution grids safer and more environmentally friendly because it operates without flammable mineral oil-based insulating fluids.
The cast resin used as insulation and for the body of the transformer has excellent electrical and mechanical properties, and is environmentally friendly and selfextinguishing.
CAREPOLE does not pose any risk to water sources or nature reserves caused by oil leaks, tank explosions, soil contamination or fires in the event of a fault. Besides, CAREPOLE does not lose any fuel in the case of an external fire. These features can reduce the costs of liability insurance.
They also increase the reliability of the distribution grid. CAREPOLE can be ordered with ready-to-use sensors, allowing you to perform your own monitoring.
The connectivity system securely transmits operational data to an advanced analytics and visualization platform, providing you real-time insights into asset health and fleet status. With these digital features, potential failures can be quickly identified and .
You may even be able to prevent issues by detecting operational irregularities at an early stage. This transparency Learn more about our digital portfolio Maintenance-free CAREPOLE is very efficient in operation, and power loss is reduced to an absolute minimum.
CAREPOLE is nearly maintenance- free, so your maintenance costs are negligible. Service activities are limited to checking the installation, vegetation conditions and wildlife management. The unit has a service life of 30+ years. There is no need to replace or change it during this time.
Easy to install You can directly replace liquidfilled overhead distribution transformers by CAREPOLE units of identical electrical power. They have identical fixing mechanisms to the pole and have been specifically developed for urban, rural or coastal outdoor installation.
Installation and grid connection are particularly simple.
Since CAREPOLE is a solid unit, it can be mounted at almost any angle on the pole and energized immedia maximum voltage capacity of 25 kV and can be equipped with a tap changer (± 2 x 2.5%), one or two high voltage bushings, and other accessories typical for overhead distribution transformers (e.g.
surge arresters, wildlife protector). Quality standards CAREPOLE from Siemens Energy offers you the highest safety standards and complies with all relevant laws and regulations. CAREPOLE meets the product requirements of the following standards: IEEE C57.12.01.
“Standard for General Requirements for Dry Type Distribution and Power Transformers” IEEE C57.12.20. “Standard for Overhead Type Distribution Transformers 500 kVA and Smaller: High Voltage, 34,500 V and Below;Low voltage, 7,970 / 13,800 Y V and Below”. Efficiency in accordance with the U.S. Department of Energy (DoE).
Other requirements as dictated by customers’ standards. Complying with the laws and regulations affecting distribution transformers Siemens Energy is closely monitoring the development of transformer regulations worldwide, e.g. the European Ecodesign Directive and US DoE rules.
Siemens Energy adheres to the rules and regulations communicated, for example, in the US and Europe, and complies with all relevant requirements for every transformer product that we supply.
As a trustworthy and responsible partner, Siemens Energy understands the importance of these regulations and will continue to monitor potential future requirements. We will continue to adapt and comply with all relevant regulatory changes.
Accessories CAREPOLE is equipped with the following accessories: Lifting lugs Mounting bracket Low-voltage ground Transformer ground connector Surge arrester (on request) Special labelling (on request) Wildlife protector (on request) Downloads CAREPOLE brochure PDF (557 KB) Download CAREPOLE press release PDF (102 KB) Download CAREPOLE brochure Portuguese PDF (694 KB) Download CAREPOLE brochure Spanish PDF (673 KB) Download For general information, please visit Transformer services Transformer laboratory
CAREPOLE | Applications and Buyer Notes
CAREPOLE is organized as a sourcing-ready Lightning Arresters reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time ques
Applications
- Initial shortlist building for related product or supplier options.
- Specification and application fit review before bulk purchasing.
- Category, keyword and detail-page comparison before sending an RFQ.
Key specifications
- Category
- Lightning ArrestersBased on visible page data; confirm exact value in the RFQ.
- Unit
- setBased on visible page data; confirm exact value in the RFQ.
Buyer tips
- State quantity range and split-delivery needs before price comparison.
- Add certification, material or inspection standards when they affect acceptance.
- For time-sensitive projects, include target arrival date and destination.
- For special applications, describe operating condition, installation environment and duty cycle.
FAQ
What should buyers confirm first?
Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.
Can buyers inquire when specs are incomplete?
Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.
How should this listing be evaluated?
Check title, category, specifications and related keywords against the actual sourcing requirement.
Source mix: ugc
Key specifications
Product sourcing keywords
These terms come from the title, visible copy and specifications, and link into matching aggregate pages.
Continue from this detail page into sourcing structure
These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.
This URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Product CategoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 0 03 10mva Capacity 11 35kv Epoxy Resin Cast Dry Type TransformerThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Meters And Protection Devices categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cables Busbar And Accessories categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Switchgear And Breakers categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Transformers And Substation Equipment categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path CompanyThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 0 2 Accuracy Micro Low Oval Gear Flow Measurement Sensor MeterThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 0 25mm 0 26mm 0 27mm G657a2 G657a1 G652d Single Mode Fiber For Drone Fpv Video And Aerial Network DaThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 0 25mm 0 27mm Ultra Light G657a2 Fiber Optic 5km 10km 20km 30km 50km 0 27mm Anti Interference Fpv DrThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 11kv Distribution Transformers sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Ip65 Switchgear Panels sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Electrical Equipment Exporters sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
PowerGridSource related sourcing paths
PowerGridSource procurement phrases
PowerGridSource related product samples
. Overview Product Parameters Packaging & Shipping Our Advantages FAQ Overview . Model NO. SCB12 Core Core-type Transfor...
Distribution Transformers Bypass Disconnect Outdoor High Voltage Isolation Switch Group Isolator Switch Air Disconnect Switch. Overview Production Scenario Testing Equipment And Reports Packaging & Shipping Engineering Case Cooperative Partner W...
Distribution Transformers Xiya Fcrg-145kv-2000A Dry Type Capacitor Composite Silicone Rubber Wall BushingXIYA FCRG-145kV-2000A Dry type capacitor composite silicone rubber wall bushing Through Wall Bushing The product are one...
Distribution Transformers Single Phase 10kVA 25kVA 37.5kVA 50kVA 100kVA 333kVA Step Down Transformer. . Model NO. TD Core Core-type Transformer Cooling Method Oil-immersed Type Transformer Winding Type Oil-Immersed Trans...
Distribution Transformers Customized High Voltage Kyn Series 33kv 1250A Metal Clad Withdraw Handcart Switchgear. Overview Detailed Photos Product Parameters Packaging & Shipping FAQ Overview . Model NO. KYN61-40.5 Voltage Level Med...
Distribution Transformers Zw7 Vacuum Circuit Breaker Vcb 33-110kv. Overview Description Specification Product Picture Company Information Overview . Model NO. ZW7 Speed High-Speed Circu...