PowerGridSourceElectrical equipment, switchgear, transformers, and power distribution components
Dfw Outdoor High-Voltage Ring Main Unit (RMU)
Electrician And Automation Instrument

Dfw Outdoor High-Voltage Ring Main Unit (RMU)

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Quote on request

Product sourcing profile

CategoryElectrician And Automation Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-04

Product introduction

Home Electrical & Electronics Power Supply & Distribution Switchgear Dfw Outdoor High-Voltage Ring Main Unit-3,000.00 1 Piece-led product discovery for buyers looking for transformers options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: industrial electrical equipment sourcing, power distribution component discovery, and rfq-ready grid supply platform.disconnect switchprotection relaycircuit breaker

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Electrician Automation Instrument

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Unit

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

PowerGridSource quality checks

Project contextCheck voltage class, installation type and project role before pricing discussion.

Use this check before moving from discovery into product comparison or RFQ submission.

Protection scopeConfirm whether protection, metering or switching requirements actually match this product.

Use this check before moving from discovery into product comparison or RFQ submission.

Tender detailBring standards, load profile and site conditions into the RFQ path.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryTransformers
Brand
Unitset
Altitude≤1000m
Ambient Temperature10℃~+40℃
ApplicationIndustrial automation and process control
Capacity1200kg
CategoryTransformers
CertificationVDE, CCC, ISO9001
Compatible Circuit BreakersVs1, Zn12V, Vd4
Compliance StandardsIEC-298
CurrentAC
CustomizationAvailable
Feature Highlightsstainless steel, digital
Five-Prevention FunctionYes (Prevents Misoperation)
Full-load Breaking Cycles>100
InstallationRemovable
Lightning Impulse Voltage75KV
Matched Termsdisconnect switch, protection relay, circuit breaker
Model NO.DFW-12
NameUnit
Number Of Mechanical Operations For Closing And Opening2000
OriginChina
Power Frequency Withstand Voltage (Phase-to-Ground)42KV/1min
Product TitleDfw Outdoor High-Voltage Ring Main Unit
Protection ClassIP4X(Cabinet)/IP2X(with Door Open)
Rated Breaking Current630A
Rated Breaking Inductive Current16A
Rated Capacitive Current Breaking Capacity45A
Rated Current630A
Rated Frequency50Hz
Rated Peak Withstand Voltage50KA
Rated Short-Circuit Breaking Current (Peak)50KA
Rated Short-Time Withstand Current20KA/4S
Rated Voltage12KV
Rated Voltagea12kv
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Relative Humidity≤95% (Daily Avg), ≤90% (Monthly Avg)
Secure paymentsEvery payment you make on Made-in-China.com is protected by the platform.
Shell MaterialStainless Steel
Shipping Cost.
SpecificationCustomized
StructureCabinet
TrademarkOEM
Transport PackageExport Standard Wooden Case
US$1,000.00-3,000.001 Piece (MOQ)
Voltage12kv
Voltage LevelHigh Voltage
Weight800~1200kg

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

Dfw Outdoor High-Voltage Ring Main Unit (RMU) sourcing decision brief

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Category
Transformers
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Project-fit electrical decision
Primary compare
Category, Brand, Unit
Adjacent category
Transformers and Substation Equipment
Next route
Medium Voltage Distribution Projects
Buyer checklist
  • Project role: Check where this item sits inside the wider distribution, retrofit or protection scope.
  • Standards fit: Compare voltage class, installation type, standards and protection scope before supplier outreach.
  • Tender handoff: Carry load profile, site conditions and compliance constraints into the RFQ path.
How should buyers use this PowerGridSource detail page?

Use the detail page to confirm whether one electrical component fits the wider project scope before opening a tender RFQ.

What should buyers compare first?

Compare voltage class, standards fit, project role and the nearest solution or procurement route.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource project-fit checks

Voltage Rating Confirm Voltage Rating before comparing offers or moving the inquiry forward.
Current Rating Confirm Current Rating before comparing offers or moving the inquiry forward.
Protection Grade Confirm Protection Grade before comparing offers or moving the inquiry forward.
Installation Type Confirm Installation Type before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PowerGridSource related product samples

Electrical project sourcing method

Project scopeRead the product inside the wider electrical project scope, not as a disconnected part.
Standards fitUse voltage class, installation type and protection scope to narrow comparisons.
Tender framingSend load profile, standards and installation context through the RFQ path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions