PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
Electrical Outdoor Pole Mounted High Voltage Vacuum Circuit Breaker
Pad Mounted Transformers

Electrical Outdoor Pole Mounted High Voltage Vacu | RFQ Sourcing Details

Pad Mounted Transformers · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryPad Mounted Transformers
Unitset
FtuBell Type or Box Type
ItemUnit Data
PoleEpoxy Resin or Silicone Rubber
TypeCircuit Breaker
SpeedNormal Type Circuit Breaker
powertransformers substations FAQ 1. What is the delivery date? Usually within a month for a HQ. 2. Do you have
CategoryPad Mounted Transformers
AvailabilityInquiry required
Updated2026-06-02

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Pad Mounted Transformers. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

. Overview Product Parameters Detailed Photos Packaging & Shipping Company Profile FAQ Overview . Model NO.

ZW32-12 Speed Normal Type Circuit Breaker Arc-extinguishing Medium Vacuum Installation Fixed Structure Vacuum Circuit Breaker Poles Number 3 Type Circuit Breaker Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection) Certification ISO , CE Standard IEC 60056 Rated Voltage 12kv Rated Current 630A/1250A Mechanical Life 10000 Times Protection CT,Zero CT Operating Mechanism Spring, Permanent Magnet Disconnector One Side or Both Sides Rated Frequency 50/60.

Hz Service Environment -40~++70 Celsius Pole Epoxy Resin or Silicone Rubber Ftu Bell Type or Box Type Delivery Time Within 30 Days Transport Package Wooden Box Specification around 140kg Trademark TENLEE Origin China HS Code Production Capacity 500 Sets Per Month ZW32-12 outdoor AC high voltage vacuum circuit breaker is post structure with separated three phases.

Vacuum arc extinguishing chamber is packed by silicone rubber and then installed in the insulation sleeve with the primary conductive elements.

The insulation sleeve is installed on the comple 2-12 vacuum circuit breaker is of excellent sealing, small size, cold- resistance, high-temperature-resistance, wind and sand resistance, damp-proof, condensation-proof.

It is in d voltage kV 12 Rated frequency Hz 50/60 Rated current A 630/1250 Rated short circuit breaking current kA 20,25 Rated short circuit making current(peak) kA 50,63 Rated short time withstand current (4S) kA 20,25 Rated peak withstand current (peak) kA 50,63 Rated operating sequence O-0.3s-CO-180s-CO Mechanical life times 10000 Rated current breaking times times 10000 Rated short circuit breaking current breaking times times 30 1min power frequency withstand voltage Between phases, phase to earth(dry) kV 42 across isolation distance(dry) kV 48 Between phases, phase to earth(wet) kV 34 Lightning impulse withstand voltage Between phases, phase to earth kV 75 across isolation distance kV 85 Secondary circuit 1 min power frequency withstand voltage kg 2 Detailed Photos DIMENSIONS Packaging & Shipping standard packaging: wooden box delivery time: within 20 days shipping: sea, air, railway, express Company Profile Combining manufacturing experience, new technology and industrial knowledge, TENLEE aims to build advanced power distribution and protection systems.

TENLEE is specialized in manufacturing a comprehensive range of solutions from 12kv to 40.5kv for indoor/outdoor systems: gas insulated switchgears ring main unit sf6 free switchgears vacuum circuit breakers sf6 circuit breakers reclosers load break switches disconnectors distribution transformers/power transformers substations FAQ 1.

What is the delivery date? Usually within a month for a HQ. 2. Do you have type tests? Yes, we have type test in China and we also pass type test in Europe. 3. Do you have other voltage ranges? Yes, we have 12kv, 24kv and 40.5kv.

Electrical | Applications and Buyer Notes

Electrical is organized as a sourcing-ready Pad Mounted Transformers reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-ti

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Pad Mounted TransformersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Ftu
Bell Type or Box TypeBased on visible page data; confirm exact value in the RFQ.
Item
Unit DataBased on visible page data; confirm exact value in the RFQ.
Pole
Epoxy Resin or Silicone RubberBased on visible page data; confirm exact value in the RFQ.
Type
Circuit BreakerBased on visible page data; confirm exact value in the RFQ.
Speed
Normal Type Circuit BreakerBased on visible page data; confirm exact value in the RFQ.
power
transformers substations FAQ 1. What is the delivery date? Usually within a montBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryPad Mounted Transformers
Unitset
FtuBell Type or Box Type
ItemUnit Data
PoleEpoxy Resin or Silicone Rubber
TypeCircuit Breaker
SpeedNormal Type Circuit Breaker
powertransformers substations FAQ 1. What is the delivery date? Usually within a month for a HQ. 2. Do you have
OriginChina
VoltageCircuit Breaker Price Electric Circuit Breaker Factories Vacuum Circuit Breaker Factories Miniature Circuit Breaker Factories Electrical Circuit Breaker Factories More Less
FunctionConventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP
StandardIEC 60056
Frequency50/60Hz Service Environment-40~++70 Celsius Pole Epoxy Resin or Silicone Rubber Ftu Bell
Model NO.ZW32-12
OperationManual Type
StructureVacuum Circuit Breaker
TrademarkTENLEE
US$700.001 Piece ( )
ProtectionCT,Zero CT
DisconnectorOne Side or Both Sides
InstallationFixed
Poles Number3
CertificationISO , CE
CustomizationAvailable
Delivery TimeWithin 30 Days
Rated Current630A/1250A
Rated Voltage12kv
Rated currentA 630/1250
Rated voltagekV 12
Specificationaround 140kg
Mechanical Life10000 Times
Mechanical lifetimes 10000
Rated Frequency50/60Hz
Rated frequencyHz 50/60
Breaking CapacityHigh Voltage Circuit Breakers
Transport PackageWooden Box
Operating MechanismSpring, Permanent Magnet
Production Capacity500 Sets Per Month
Service Environment40~++70 Celsius
Arc-extinguishing MediumVacuum
Rated operating sequence0.3s-180s
across isolation distancekV 85
Rated current breaking timestimes 10000
across isolation distance(dry)kV 48
Between phases, phase to earth(wet)kV 34
Lightning impulse withstand voltageBetween phases, phase to earth kV 75
Rated peak withstand current (peak)kA 50,63
Rated short circuit breaking currentkA 20,25
1min power frequency withstand voltageBetween phases, phase to earth(dry) kV 42
Rated short time withstand current (4S)kA 20,25
Rated short circuit making current(peak)kA 50,63
Rated short circuit breaking current breaking timestimes 30
Secondary circuit 1 min power frequency withstand voltagekg 2

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples