PowerGridSourceElectrical equipment, switchgear, transformers, and power distribution components
Fu A Split Core Busbar Type Current Transformer
Electrician And Automation Instrument

Fu A Split Core Busbar Type Current Transformer

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Quote on request

Product sourcing profile

CategoryElectrician And Automation Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-04

Product introduction

Home Electrical & Electronics Power Transmission & Transformer Instrument Transformer Current Instrument Transformer Fu A Split Core Busbar Type Current Transformer US$11.00 10 Pieces-led product discovery for buyers looking for transformers options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: industrial electrical equipment sourcing, power distribution component discovery, and rfq-ready grid supply platform.transformerbusbarenergy meter

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Electrician Automation Instrument

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Energy Meter

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

PowerGridSource quality checks

Project contextCheck voltage class, installation type and project role before pricing discussion.

Use this check before moving from discovery into product comparison or RFQ submission.

Protection scopeConfirm whether protection, metering or switching requirements actually match this product.

Use this check before moving from discovery into product comparison or RFQ submission.

Tender detailBring standards, load profile and site conditions into the RFQ path.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryTransformers
Brand
Unitset
1000A/1AYES YES YES
1000A/1VYES YES YES
1000A/2VYES YES YES
1000A/333mVYES YES
1000A/5AYES YES
1000A/5VYES YES YES
1500A/5AYES YES
2000A/1AYES YES YES
2000A/1VYES YES YES
2000A/2VYES YES YES
2000A/333mVYES YES
2000A/5AYES YES
2000A/5VYES YES YES
2500A/5AYES YES
3000A/1AYES YES YES
3000A/1VYES YES YES
3000A/2VYES YES YES
3000A/333mVYES YES
3000A/5AYES YES
3000A/5VYES YES YES
300A/5AYES YES
4000A/1AYES YES YES
4000A/1VYES YES YES
4000A/2VYES YES YES
4000A/333mVYES YES
4000A/5AYES YES
4000A/5VYES YES YES
5000A/1AYES YES YES
5000A/1VYES YES YES
5000A/2VYES YES YES
5000A/333mVYES YES
5000A/5AYES YES
5000A/5VYES YES YES
500A/1VYES YES YES
500A/2VYES YES YES
500A/333mVYES YES
500A/5AYES YES
500A/5VYES YES YES
600A/5AYES YES
800A/5AYES YES
Accuracy0.2%, 0.5%, 1%
ApplicationElectrical and power distribution
Burden2.5va-20va
Capacity3.000kg
CategoryTransformers
ColorWhite and grey
ConditionNo existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.
CustomizationAvailable
Dielectric Strength3kv 50Hz/60Hz at 1 Minute
Dielectric strength3KV 50Hz/60Hz at 1 minute
Dimensions160 x 80mm
Dimensions (W×D×H)(mm)144 x 227 x 54
Dimensions(mm)144 X 227 X 54
FU-100300-3000A ≤10VA 333mV, 1V, 5V, 1A, 5A φ100 170 x 184.5 x 41 1
FU-165-200A ≤10 Ohm 333mV, 1V, 5V, 100mA φ16 38 x 55 x 18 0.06
FU-32100-600A ≤10VA 333mV, 1V, 5V, 1A, 5A φ32 110 x 130 x 41 0.7
FU-36100-600A ≤2.5VA 333mV, 1V, 5V, 1A, 5A φ10, φ16, φ24, φ36 26 × 43 × 27 31 × 50 × 30 43 ×73 × 39 60 × 89 × 43 0.1, 0.12, 0.2, 0.35
FU-80100-1200A ≤5VA 333mV, 1V, 5V, 1A, 5A φ30, φ55, φ80 88 x 129 x 28 108 x 155 x 28 138 x 193 x 28 0.4, 0.55, 0.6
FU120200-4000A ≤10VA 333mV, 1V, 5V, 1A, 5A 120 x 130, 120 x 30 166 x 110 x 49 166 x 208 x 49 1.2, 1.7
FU160500-5000A ≤20VA 1A, 5A 160 x 80 144 x 227 x 54 2.8
Feature Highlightsdigital, precision
Frequency Range40Hz...2000Hz
Frequency range40Hz...2000Hz
InstallationActive Type
Installation categoryCAT IV 600V AC IEC/EN 61010-1
Insulating MediumCommon Insulating Materials
Internal structureBusbar type Design
Magnetic Circuit StructureSingle Stage Type
Matched Termstransformer, busbar, energy meter
MaterialSilicon steel sheets+enameled wire+ABS+94V-0
Max. Jaw Opening160 X 80mm
Max. jaw opening160 x 80mm
ModelPrimary rated current Rated load Secondary output Aperture (mm) Description (mm) Weight (kg)
Nominal input current (primary current)300A/400A/500A/600A/750A/800A/1000A/1200A/1250A/1500A/2000A/2500A/3000A/3200A/4000A/5000A
Operating temperature25°C to +55°C
Operation ConditionIndoor
OriginBeijing, China
OutputK1, K2 or S1, S2
Output Signal1A, 5A AC Optional 333mv AC or 100mv-2V Optional
Output signal1A, 5A AC optional 333mV AC or 100mV-2V optional
Overload withstand1.2 times rated current continuously
Product TitleFu A Split Core Busbar Type Current Transformer
Protection Level3.0V0-P
Protection level3.0V0-P
PurposeMeasuring current transformer
Ratio300A/400A/500A/600A/750A/800A/1000A/1200A/1250A/15
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Relative humidity0-85% non-condensing
Secure paymentsEvery payment you make on Made-China.com is protected by the platform.
Shipping Cost.
Specification0.2%, 0.5s, 0.5%
StandardsIEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13
System Voltage720V (0.72kv)
System voltage720V (0.72kV)
Temperature25°c
TrademarkGFUVE
Transport PackageStandard Export Box
TypeCurrent Transformer
US$11.0010 Pieces (MOQ)
UsageMeasurement
Using environmentIndoor
Voltage3kv
Voltage Transformation PrincipleElectromagnetic Type
Weight (Kg)2.8
Weight (kg)2.8
Winding FormSingle Layer & Tightly Wound Type

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

Fu A Split Core Busbar Type Current Transformer sourcing decision brief

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Category
Transformers
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Project-fit electrical decision
Primary compare
Category, Brand, Unit
Adjacent category
Transformers and Substation Equipment
Next route
Energy Metering and Protection Upgrades
Buyer checklist
  • Project role: Check where this item sits inside the wider distribution, retrofit or protection scope.
  • Standards fit: Compare voltage class, installation type, standards and protection scope before supplier outreach.
  • Tender handoff: Carry load profile, site conditions and compliance constraints into the RFQ path.
How should buyers use this PowerGridSource detail page?

Use the detail page to confirm whether one electrical component fits the wider project scope before opening a tender RFQ.

What should buyers compare first?

Compare voltage class, standards fit, project role and the nearest solution or procurement route.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource project-fit checks

Voltage Rating Confirm Voltage Rating before comparing offers or moving the inquiry forward.
Current Rating Confirm Current Rating before comparing offers or moving the inquiry forward.
Protection Grade Confirm Protection Grade before comparing offers or moving the inquiry forward.
Installation Type Confirm Installation Type before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PowerGridSource related product samples

Electrical project sourcing method

Project scopeRead the product inside the wider electrical project scope, not as a disconnected part.
Standards fitUse voltage class, installation type and protection scope to narrow comparisons.
Tender framingSend load profile, standards and installation context through the RFQ path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions