PowerGridSourceElectrical equipment, switchgear, transformers, and power distribution components
GF2018 Wireless Current-Sensing High-Voltage Power Load Recorder
Electrician And Automation Instrument

GF2018 Wireless Current-Sensing High-Voltage Power Load Recorder

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Quote on request

Product sourcing profile

CategoryElectrician And Automation Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-04

Product introduction

Home Instruments & Meters Electronic Instrument Calibrator GF2018 Wireless Current-Sensing High-Voltage Power Load Recorder US$18, Sets US$16, + Sets Start Order Request Send Inquiry Chat Now Still deciding? Get samples of $ ! US$ 18000/Set OPowerGridSource curates RFQ-led product discovery for buyers looking for transformers options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: industrial electrical equipment sourcing, power distribution component discovery, and rfq-ready grid supply platform.circuit breakerenergy metertransformer

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Electrician Automation Instrument

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Energy Meter

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

PowerGridSource quality checks

Project contextCheck voltage class, installation type and project role before pricing discussion.

Use this check before moving from discovery into product comparison or RFQ submission.

Protection scopeConfirm whether protection, metering or switching requirements actually match this product.

Use this check before moving from discovery into product comparison or RFQ submission.

Tender detailBring standards, load profile and site conditions into the RFQ path.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryTransformers
Brand
Unitset
100 to 300A1A
Accuracy±1%
After-sales Service24 Hour Service
Amps 1 to 99.9A0.1A
Amps accuracy±1% of reading plus 2 counts
ApplicationElectrical and power distribution
Battery3.6 Volt Lithium Battery,9000mAh;Battery Can Be R
Capacity6.000kg
Carrying Case(Kg)5.2
Carrying case(kg)5.2
CategoryTransformers
CertificationCE, CCC
Communication433m, 868m or 915m (Option)
Communication Distance(Wireless)Max 100m
Communication distance(wireless)Max 100m
Current0 to 400A;0 to 800A;0 to 1500A;0 to 3500A
Current Output0A-3500A
CustomizationAvailable
CustomizedCustomized
Data recording interval1min, 5min, 10min,15min, 30min;Time can be set from 1second to 60 minutes
Drive space15 MB to load software, 10 MB of operating Space
Feature Highlightsdigital
Frequency60Hz-63 Hz) or 50Hz-53 Hz) Models Availab
GF2018Ammeter Data Logger
InstallationInstallation with electricity;Disassemble with electricity
LCD DisplayWith LCD Display
Matched Termscircuit breaker, energy meter, transformer
Model NO.GF2018
Operating Temperature40°C to 60°C
Operating temperature40°C to 60°C
OriginBeijing
PowerElectricity
Processor100 MHz or Higher (200 MHz or Higher Recommended)
Product TitleGF2018 Wireless Current-Sensing High-Voltage Power Load Recorder
RAM32 MB, 64m Recommended
Recording ammeter kit3 wireless current sensors-LinkSoftware software
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secure paymentsEvery payment you make on Made-China.com is protected by the platform.
Sensor Openingup to 3.3 Cm
Sensor openingUp to 3.3 cm
Shipping Cost.
Software requirementsPC-Linksoftware & microsoft Excel
SpecificationWeight (kg) 5.2
Temperature40°c
TrademarkGFUVE
Transport PackageStandard Export Wooden Box
Use of PositionOutdoor or Indoor
Use of positionOutdoor or indoor
Voltage69kv,35kv,33kv,20kv, 10kv, 6kv, 0.38kv
Voltage Output0.38kv-69kv
Warranty2 Years
Weight (Kg)0.38(One Current Sensor)
Weight (kg)0.38(one current sensor)

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

GF2018 Wireless Current-Sensing High-Voltage Power Load Recorder sourcing decision brief

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Category
Transformers
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Project-fit electrical decision
Primary compare
Category, Brand, Unit
Adjacent category
Transformers and Substation Equipment
Next route
Medium Voltage Distribution Projects
Buyer checklist
  • Project role: Check where this item sits inside the wider distribution, retrofit or protection scope.
  • Standards fit: Compare voltage class, installation type, standards and protection scope before supplier outreach.
  • Tender handoff: Carry load profile, site conditions and compliance constraints into the RFQ path.
How should buyers use this PowerGridSource detail page?

Use the detail page to confirm whether one electrical component fits the wider project scope before opening a tender RFQ.

What should buyers compare first?

Compare voltage class, standards fit, project role and the nearest solution or procurement route.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource project-fit checks

Voltage Rating Confirm Voltage Rating before comparing offers or moving the inquiry forward.
Current Rating Confirm Current Rating before comparing offers or moving the inquiry forward.
Protection Grade Confirm Protection Grade before comparing offers or moving the inquiry forward.
Installation Type Confirm Installation Type before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PowerGridSource related product samples

Electrical project sourcing method

Project scopeRead the product inside the wider electrical project scope, not as a disconnected part.
Standards fitUse voltage class, installation type and protection scope to narrow comparisons.
Tender framingSend load profile, standards and installation context through the RFQ path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions