PowerGridSourceElectrical equipment, switchgear, transformers, and power distribution components
GR8 Intermediate Relay:Boost Control with Supreme Reliability
Electrician And Automation Instrument

GR8 Intermediate Relay:Boost Control with Supreme Reliability

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Quote on request

Product sourcing profile

CategoryElectrician And Automation Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-05

Product introduction

Description GR8 Intermediate Relay Product Features: Voltage Range (Optional): AC/DC 12V, 24V, 48V, 110V, and AC 230V, offering compatibility with various power supplies for flexible application in diverse electrical environments. Multiple Models Available: In. Power. Grid. Source curates RFQ-led product discovery for buyers looking for relays options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: industrial electrical equipment sourcing, power distribution component discovery, and rfq-ready grid supply platform.relaycontactor

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Electrician Automation Instrument

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Geya Electrical Equipment

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

PowerGridSource quality checks

Project contextCheck voltage class, installation type and project role before pricing discussion.

Use this check before moving from discovery into product comparison or RFQ submission.

Protection scopeConfirm whether protection, metering or switching requirements actually match this product.

Use this check before moving from discovery into product comparison or RFQ submission.

Tender detailBring standards, load profile and site conditions into the RFQ path.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryRelays
BrandGEYA Electrical Equipment Supply
Unitset
ApplicationIndustrial automation and process control
BurdenAC.max 12VA/DC.max1.9W
CategoryRelays
Current rating16A/AC1 8A/AC1 16A/AC1
Dimension90×18×64mm
Electrical life(AC1)1*10 5
Matched Termsrelay
Max.cable size(mm²)solid wire max.1×2.5or 2×1.5/withsleeve max.1×2.5(AWG12)
Max.chargeover time40ms
Mechanical life1*10 7
Min.breaking capacity DC500mW
ModelGR8-116 GR8-208 GR8-308 GR8-316
Mounting/DIN railDin rail EN/IEC 60715
Number of contact1×SPDT 2×SPDT 3×SPDT 3×SPDT
Operating positionany
Operating temperature20℃ to+55℃
Output indicationRed LED
Overvoltage cathegoryIII.
Pollution degree2
Product TitleGR8 Intermediate Relay:Boost Control with Supreme Reliability
Protection degreeIP40 for front panel/IP20 terminals
Reset timemax.200ms
Storage temperature35℃ to+75℃
Supply terminalsA1-A2 A1-A2
Supply voltage tolerance15%;+10%
Switching voltage250VAC/24VDC
Voltage12v
Voltage rangeAC/DC 12V、24V、48V、110V AC/DC 12V、24V
Weight44g/54g 50g/60g 72g/82g 86g/96

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

GR8 Intermediate Relay:Boost Control with Supreme Reliability sourcing decision brief

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Category
Relays
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Project-fit electrical decision
Primary compare
Category, Brand, Unit
Adjacent category
Transformers and Substation Equipment
Next route
Medium Voltage Distribution Projects
Buyer checklist
  • Project role: Check where this item sits inside the wider distribution, retrofit or protection scope.
  • Standards fit: Compare voltage class, installation type, standards and protection scope before supplier outreach.
  • Tender handoff: Carry load profile, site conditions and compliance constraints into the RFQ path.
How should buyers use this PowerGridSource detail page?

Use the detail page to confirm whether one electrical component fits the wider project scope before opening a tender RFQ.

What should buyers compare first?

Compare voltage class, standards fit, project role and the nearest solution or procurement route.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource project-fit checks

Voltage Rating Confirm Voltage Rating before comparing offers or moving the inquiry forward.
Current Rating Confirm Current Rating before comparing offers or moving the inquiry forward.
Protection Grade Confirm Protection Grade before comparing offers or moving the inquiry forward.
Installation Type Confirm Installation Type before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PowerGridSource related product samples

Electrical project sourcing method

Project scopeRead the product inside the wider electrical project scope, not as a disconnected part.
Standards fitUse voltage class, installation type and protection scope to narrow comparisons.
Tender framingSend load profile, standards and installation context through the RFQ path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions