Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Quote on request

Product sourcing profile

CategoryElectrician And Automation Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-05

Product introduction

Description The GYR10NE Electronic RCBO (Residual Current Circuit Breaker with Overcurrent Protection) is a highly efficient, compact 1P+N circuit breaker designed for AC 50/60. Hz networks with a rated voltage up to 240V and a rated current up to 40A. When pers. Power. Grid. Source curates RFQ-led product discovery for buyers looking for circuit breakers options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: industrial electrical equipment sourcing, power distribution component discovery, and rfq-ready grid supply platform.electrical equipmentcircuit breakerpower supply

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Electrician Automation Instrument

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Electrical Equipment

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

PowerGridSource quality checks

Project contextCheck voltage class, installation type and project role before pricing discussion.

Use this check before moving from discovery into product comparison or RFQ submission.

Protection scopeConfirm whether protection, metering or switching requirements actually match this product.

Use this check before moving from discovery into product comparison or RFQ submission.

Tender detailBring standards, load profile and site conditions into the RFQ path.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryCircuit Breakers
BrandGEYA Electrical Equipment Supply
Unitset
6~4030, 100, 300 ≤0.1 ≤0.08 ≤0.04 ≤0.04 ≤0.04
ApplicationElectrical and power distribution
CategoryCircuit Breakers
Class of protectionIP20
Enterprise codeWith N poles electronic type
GYR10N E
IΔn2IΔn 5IΔn 5A~200A 500A
Matched Termselectrical equipment, circuit breaker, power supply
ParameterSpecification
Poles1P+N
Product TitleGYR10NE RCBO 1P+N Type A/Type AC-GEYA Electrical Equipment Supply
Product model– –
Rated Current (In)6A, 10A, 16A, 20A, 25A, 32A, 40A
Rated Voltage (Un)230/240V
Rated current In(A)Rated residual action current IΔn(mA) Residual current breaking time (s)
Rated impact tolerance voltage (Uimp)4kV
Rated insulation voltage (Ui)500V
Rated limit Remaining short circuit current (IΔc)4500A/6000A
Rated limit short circuit current (Inc)4500A/6000A
Rated on and off capacity (Im)500A
Rated residual action current (IΔn)0.03A, 0.1A, 0.3A
Rated residual switching and breaking capacity (IΔm)500A
Residual current action typeType A, Type AC
Tightening moment1.2N
Trip CurveB, C
Voltage240v
Working Frequency50/60Hz

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

GYR10NE RCBO 1P+N Type A/Type AC - GEYA Electrical Equipment Supply sourcing decision brief

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Category
Circuit Breakers
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Project-fit electrical decision
Primary compare
Category, Brand, Unit
Adjacent category
Transformers and Substation Equipment
Next route
Medium Voltage Distribution Projects
Buyer checklist
  • Project role: Check where this item sits inside the wider distribution, retrofit or protection scope.
  • Standards fit: Compare voltage class, installation type, standards and protection scope before supplier outreach.
  • Tender handoff: Carry load profile, site conditions and compliance constraints into the RFQ path.
How should buyers use this PowerGridSource detail page?

Use the detail page to confirm whether one electrical component fits the wider project scope before opening a tender RFQ.

What should buyers compare first?

Compare voltage class, standards fit, project role and the nearest solution or procurement route.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource project-fit checks

Voltage Rating Confirm Voltage Rating before comparing offers or moving the inquiry forward.
Current Rating Confirm Current Rating before comparing offers or moving the inquiry forward.
Protection Grade Confirm Protection Grade before comparing offers or moving the inquiry forward.
Installation Type Confirm Installation Type before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PowerGridSource related product samples

Electrical project sourcing method

Project scopeRead the product inside the wider electrical project scope, not as a disconnected part.
Standards fitUse voltage class, installation type and protection scope to narrow comparisons.
Tender framingSend load profile, standards and installation context through the RFQ path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions