PowerGridSourceElectrical equipment, switchgear, transformers, and power distribution components
T-3630 10kv 15kv High Voltage Insulation Resistance Tester - Cable Insulation Testing
Electrician And Automation Instrument

T-3630 10kv 15kv High Voltage Insulation Resistance Tester - Cable Insulation Testing

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Quote on request

Product sourcing profile

CategoryElectrician And Automation Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-04

Product introduction

Home Instruments & Meters Meter for Electricity Resistance Meter Insulation Resistance Tester T-3630 10kv 15kv High Voltage Insulation Resistance Tester-Cable Insulation Testing US$3, Pieces US$3,250.00 5+ Pieces Start Order Request Send Inquiry ChPowerGridSource curates RFQ-led product discovery for buyers looking for transformers options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: industrial electrical equipment sourcing, power distribution component discovery, and rfq-ready grid supply platform.electrical equipmentcircuit breakerenergy meter

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Electrician Automation Instrument

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Electrical Equipment

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

PowerGridSource quality checks

Project contextCheck voltage class, installation type and project role before pricing discussion.

Use this check before moving from discovery into product comparison or RFQ submission.

Protection scopeConfirm whether protection, metering or switching requirements actually match this product.

Use this check before moving from discovery into product comparison or RFQ submission.

Tender detailBring standards, load profile and site conditions into the RFQ path.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryTransformers
Brand
Unitset
AC Test Voltage Range0~750V
Accuracy3%
After-sales Service24 Hours Online
Alarm FunctionYes
ApplicationElectrical and power distribution
BacklightYes
Capacitance10NF~50UF;Resolution: 10NF
Capacity2.800kg
CategoryTransformers
CertificationRoHS, CE
CommunicationUSB Port
CustomizationAvailable
CustomizedNon-Customized
DAR and PIYes
DC Current0.1na~6mA;Resolution:0.1na
DC Test Voltage Range0~1000V
Dar and PiYes
Data Storage500 GROUPS
Dimensions240x188x85mm
Dimensions (W×D×H) (mm)240x188x85
Display TypeDigital Only
Feature Highlightsdigital, automatic
FunctionInsulation Resistance Test, Voltage Test, DC Curre
Insulation Resistance≥50MΩ (500V between circuit and shell)
Insulation Resistance Range0.01m~50t
Insulation resistance range0.01MΩ~50TΩ
LCD Display108mmx65mm, 4-Bit LCD Display, Gray Screen Backlig
LCD display108mm×65mm, 4-bit LCD display, gray screen backlight
MODELT-3630A T-3630B T-3630C
Matched Termselectrical equipment, circuit breaker, energy meter
Max Output Voltage5KV 10KV 15KV
Model NO.T-3630
Operating Temperature10°C to +50°C
OriginChina
Output Short-Circuit CurrentMore Than 6mA
Output short-circuit Current≥6mA
PC softwareYes
Power ConsumptionStandby: 30mA Max(backlight off), Turn on backlight: 42mA Max, Measure:300mA Max(backlight off)
Power Supply12V Rechargeable Battery
Product TitleT-3630 10kv 15kv High Voltage Insulation Resistance Tester-Cable Insulation Testing
Rated Voltage Range100V, 250V, 500V, 1000V, 2500V, 5000V, 10kv, 15kv
Rated voltage range100v, 250V, 500V, 1000V, 2500V, 5000V, 10KV, 15KV
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Relative humidity≤90%RH
Resistance Range10TΩ 35TΩ 50TΩ
Resolution0.01MΩ
Secure paymentsEvery payment you make on Made-China.com is protected by the platform.
Shipping Cost.
Specification240x188x85mm
StandardIEC61010-1, IEC , IEC61557-1,2,5, IEC60529
Storage Temperature40°C to 70°C
Temperature10°c
Test cableHV red cable 3m, black 1.5m, green 1.5m
TrademarkGFUVE
Voltage10kv
Warranty3 Years
Weight (kg)2.75
Withstand voltageAC3kV/50Hz 1min (between circuit and housing)

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

T-3630 10kv 15kv High Voltage Insulation Resistance Tester - Cable Insulation Testing sourcing decision brief

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Category
Transformers
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Project-fit electrical decision
Primary compare
Category, Brand, Unit
Adjacent category
Transformers and Substation Equipment
Next route
Medium Voltage Distribution Projects
Buyer checklist
  • Project role: Check where this item sits inside the wider distribution, retrofit or protection scope.
  • Standards fit: Compare voltage class, installation type, standards and protection scope before supplier outreach.
  • Tender handoff: Carry load profile, site conditions and compliance constraints into the RFQ path.
How should buyers use this PowerGridSource detail page?

Use the detail page to confirm whether one electrical component fits the wider project scope before opening a tender RFQ.

What should buyers compare first?

Compare voltage class, standards fit, project role and the nearest solution or procurement route.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource project-fit checks

Voltage Rating Confirm Voltage Rating before comparing offers or moving the inquiry forward.
Current Rating Confirm Current Rating before comparing offers or moving the inquiry forward.
Protection Grade Confirm Protection Grade before comparing offers or moving the inquiry forward.
Installation Type Confirm Installation Type before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PowerGridSource related product samples

Electrical project sourcing method

Project scopeRead the product inside the wider electrical project scope, not as a disconnected part.
Standards fitUse voltage class, installation type and protection scope to narrow comparisons.
Tender framingSend load profile, standards and installation context through the RFQ path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions