PowerGridSourceElectrical equipment, switchgear, transformers, and power distribution components
The GF302D Equipment: for Portable Testing of Three-Phase Kwh Meters
Electrician And Automation Instrument

The GF302D Equipment: for Portable Testing of Three-Phase Kwh Meters

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Quote on request

Product sourcing profile

CategoryElectrician And Automation Instrument
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-04

Product introduction

Home Instruments & Meters Electronic Instrument Calibrator The GF302D Equipment: for Portable Testing of Three-Phase Kwh Meters US$40,000.00 1 Piece-sales Service: 2PowerGridSource curates RFQ-led product discovery for buyers looking for transformers options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: industrial electrical equipment sourcing, power distribution component discovery, and rfq-ready grid supply platform.circuit breakerenergy meterpower supply

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Equipment

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Electrician Automation Instrument

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

PowerGridSource quality checks

Project contextCheck voltage class, installation type and project role before pricing discussion.

Use this check before moving from discovery into product comparison or RFQ submission.

Protection scopeConfirm whether protection, metering or switching requirements actually match this product.

Use this check before moving from discovery into product comparison or RFQ submission.

Tender detailBring standards, load profile and site conditions into the RFQ path.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryTransformers
Brand
Unitset
302D120010.1% 0-600V 0-120A 22KG
302D120050.05% 0-600V 0-120A 22KG
302D12010.1% 0-500V 0-12A 15KG
302D12050.05% 0-500V 0-12A 15KG
302D24010.1% 0-600V 0-24A 16KG
302D24050.05% 0-600V 0-24A 16KG
302D6010.1% 0-380V 0-6A 12KG
302D6050.05% 0-380V 0-6A 12KG
Accuracy0.05%, 0.1%
Active Power Pulse Output5V, 10mA
Active power energy0.05%RG
Active power measuring accuracy0.05%RG
Active power pulse output5V, 10mA
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Adjustment range0-120)%RG
After-sales Service24 Hour Service
Ambient Temperature10°C to +40°C
Ambient temperature10°C to +40°C
Apparent power measuring accuracy0.05%RG
ApplicationElectrical and power distribution
Capacity22kg
CategoryTransformers
CertificationFDA, CE, IAF, CCC, Ilac.Mra
Communication PortRS232
Communication portRS232
Current Output120A
Current Output (AC)1mA to 120A
CustomizationAvailable
CustomizedCustomized
Declaration of conformityCE certified
Degree of protectionIP20
Dimensions600 x 700 x 285mm
Dimensions (W×D×H)(mm)500 × 600 × 175
Distortion0.3%-capacitive load
Energy pulse typeSupport active and reactive pulse, the highest frequency power pulse input is 180K.
Feature Highlightsdigital, precision
Frequency Output40Hz-70Hz
HS Code903033
Harmonic content0-40%
Harmonic number2-51times or 2-63times
Harmonic phase0-359.99
Harmonic setting accuracy(10%±0.1%)RD (2)
Isolation protectionIEC 61010-1:2001
LCD DisplayWithout LCD Display
Matched Termscircuit breaker, energy meter, power supply
Measurement accuracy0.0005
Measurement category300V CAT III, 600V CAT II
Measuring accuracy0.05%RG or 0.02%RG
Model NO.GF302D
NO.Accuracy Voltage range Current range Weight
OriginChina
Output adjustment fineness10, 1, 0.1, 0.01 as optional.
Output adjustment range0 °-359.999 °
Output loadeach phase 25VA, 50VA, 100VA
Phase Angle0°to 359.999°
PowerElectricity
Power Factor1 ~ 0 ~ 1
Power Pulse TypeActive Pulse, Reactive Pulse
Power SupplyOne Phase AC 85-265V, Frequency 50/60Hz.
Power pulse typeActive pulse, reactive pulse
Power supplyOne phase AC 85-265V, frequency 50/60Hz.
Product TitleThe GF302D Equipment: for Portable Testing of Three-Phase Kwh Meters
Range (I1, I2, I3)200mA, 1A, 5A, 20A, 100A;Max 120A
Range (U1, U2, U3)57.7V, 100V, 220V, 380V;Max 500V or 69.3V, 120V, 240V, 480V (optional);Max 600V
Reactive power energy0.1%RG
Reactive power measuring accuracy0.1%RG
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Relative Humidity35%-85%
Relative humidity35%-85%
Resolution0.01°
Secure paymentsEvery payment you make on Made-China.com is protected by the platform.
Shipping Cost.
Specification600 x 700 x 285mm
Stability0.01%/120s
StandardIEC 62053-21,22,23;IEC60736;ANSI C
Temperature10°c
TrademarkGFUVE
Transport PackagePlywood Box
US$40,000.001 Piece (MOQ)
Voltage380v
Voltage Output380V
WarrantyThree Years
Weight (kg)22
Weight(Kg)22kg

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

The GF302D Equipment: for Portable Testing of Three-Phase Kwh Meters sourcing decision brief

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Category
Transformers
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Project-fit electrical decision
Primary compare
Category, Brand, Unit
Adjacent category
Transformers and Substation Equipment
Next route
Energy Metering and Protection Upgrades
Buyer checklist
  • Project role: Check where this item sits inside the wider distribution, retrofit or protection scope.
  • Standards fit: Compare voltage class, installation type, standards and protection scope before supplier outreach.
  • Tender handoff: Carry load profile, site conditions and compliance constraints into the RFQ path.
How should buyers use this PowerGridSource detail page?

Use the detail page to confirm whether one electrical component fits the wider project scope before opening a tender RFQ.

What should buyers compare first?

Compare voltage class, standards fit, project role and the nearest solution or procurement route.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource project-fit checks

Voltage Rating Confirm Voltage Rating before comparing offers or moving the inquiry forward.
Current Rating Confirm Current Rating before comparing offers or moving the inquiry forward.
Protection Grade Confirm Protection Grade before comparing offers or moving the inquiry forward.
Installation Type Confirm Installation Type before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PowerGridSource related product samples

Electrical project sourcing method

Project scopeRead the product inside the wider electrical project scope, not as a disconnected part.
Standards fitUse voltage class, installation type and protection scope to narrow comparisons.
Tender framingSend load profile, standards and installation context through the RFQ path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions