PowerGridSourceElectrical equipment, switchgear, transformers, and power distribution components
YTJL10-720JE-32G Deeply Integrated Electrical Equipment Supplies Electronic Sensor (Current/Voltage Transformer)
Electrical Engineering

YTJL10-720JE-32G Deeply Integrated Electrical Equipment Supplies Electronic Sensor (Current/Voltage Transformer)

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Quote on request

Product sourcing profile

CategoryElectrical Engineering
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-04

Product introduction

YTJL10-720JE-32G Deeply Integrated Electrical Equipment Supplies Electronic Sensor (Current/Voltage Transformer) US$320.00 1 Piece (MOQ) Product Specifications Select Now CT VT Transformer Send Inquiry Chat Now Still deciding? Get samples of $ ! US$ 450/Piece. Power. Grid. Source curates RFQ-led product discovery for buyers looking for transformers options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: industrial electrical equipment sourcing, power distribution component discovery, and rfq-ready grid supply platform.electrical equipmenttransformercircuit breaker

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Deeply Integrated Electrical Equipment

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Supplies Electronic Sensor

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

PowerGridSource quality checks

Project contextCheck voltage class, installation type and project role before pricing discussion.

Use this check before moving from discovery into product comparison or RFQ submission.

Protection scopeConfirm whether protection, metering or switching requirements actually match this product.

Use this check before moving from discovery into product comparison or RFQ submission.

Tender detailBring standards, load profile and site conditions into the RFQ path.

Use this check before moving from discovery into product comparison or RFQ submission.

Key specifications

CategoryTransformers
BrandTianjin Pinggao In
Unitset
Accuracy classPhase voltage: 0.5 (3P)
Allowable wear thickness of contacts3 mm
ApplicationFood and beverage processing
Average closing speed0.6±0.2m/s
Average opening speed1.1±0.2m/s
BrandPG
Breaking times of rated short-circuit breaking current50 times
CT VT Transformer10
CategoryTransformers
CertificationISO9001
Circuit resistance at the lower limit of rated contact pressure≤40 μΩ
Clearance between contacts9±1mm
Contact initial pressure≥1,400 N
Cooling MethodDry-type Transformer
CoreCore-type Transformer
CustomizationAvailable
Feature Highlightsdigital
First power frequency withstand voltage of the rated section42/48 kV
Frequency CharacteristicsPower Frequency
HS Code850431
Insulation resistance>1000MΩ
Matched Termselectrical equipment, transformer, circuit breaker
Max. contact bounce duration2ms
Maximum rebound during opening≤2 mm
Mechanical life30,000 times
Model NO.YTJL10-720JE-32G
Non-simultaneity of contact opening and closing≤1ms
OriginChina
Partial discharge≤20 pC
PhaseThree
Phase voltage(10 kV/√3)/(3.25 V/√3)
Product TitleYTJL10-720JE-32G Deeply Integrated Electrical Equipment Supplies Electronic Sensor
Project NameParameter
Rated contact pressure1,800±200 N
Rated currentPhase current: 600A/1V;zero-sequence current: 20A/0.2V
Rated frequency50/60 Hz
Rated lightning impulse withstand voltage75/85 kV
Rated load2MΩ
Rated operating sequenceO-0.3s-CO-180s-CO
Rated symmetrical short-circuit breaking current20 kA
Rated voltagePhase voltage: (10 kV/√3)/(3.25 V/√3)
Reaction force of contacts at rated clearance165±30N
Secondary power frequency withstand voltage3 kV/1 min
Self-closing force70±30 N
Shape of CoreRing
Shelf life30 years
SpecificationYTJL10-720JE-32G
Temperature40°c
TrademarkPG
US$320.001 Piece (MOQ)
UsageCombined Transformer
Voltage10 kv
Winding TypeSeparated Winding Transformer
Zero-sequence voltage(10 kV/√3)/(6.5 V/3)

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

YTJL10-720JE-32G Deeply Integrated Electrical Equipment Supplies Electronic Sensor (Current/Voltage Transformer) sourcin...

Electrical detail pages should help buyers judge whether one component fits the wider project scope, standards path and protection role before tender RFQ.

Category
Transformers
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Project-fit electrical decision
Primary compare
Category, Brand, Unit
Adjacent category
Transformers and Substation Equipment
Next route
Medium Voltage Distribution Projects
Buyer checklist
  • Project role: Check where this item sits inside the wider distribution, retrofit or protection scope.
  • Standards fit: Compare voltage class, installation type, standards and protection scope before supplier outreach.
  • Tender handoff: Carry load profile, site conditions and compliance constraints into the RFQ path.
How should buyers use this PowerGridSource detail page?

Use the detail page to confirm whether one electrical component fits the wider project scope before opening a tender RFQ.

What should buyers compare first?

Compare voltage class, standards fit, project role and the nearest solution or procurement route.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource project-fit checks

Voltage Rating Confirm Voltage Rating before comparing offers or moving the inquiry forward.
Current Rating Confirm Current Rating before comparing offers or moving the inquiry forward.
Protection Grade Confirm Protection Grade before comparing offers or moving the inquiry forward.
Installation Type Confirm Installation Type before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PowerGridSource related product samples

Electrical project sourcing method

Project scopeRead the product inside the wider electrical project scope, not as a disconnected part.
Standards fitUse voltage class, installation type and protection scope to narrow comparisons.
Tender framingSend load profile, standards and installation context through the RFQ path.

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions