Product specs

CategoryPower Cables
Unitset
IcuIce
11kW18…25A
15kW25…32A MS kA 10 kA
22kW30…42A
30kW52…65A
TypeMS116 MS132 MS165
CategoryPower Cables
AvailabilityInquiry required
Updated2026-05-31

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Power Cables. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

. Overview Specification Company Profile FAQ Packaging & Shipping Overview . Model NO.

MS116 Speed Normal Type Circuit Breaker Arc-extinguishing Medium Air Installation Fixed Structure MCB Poles Number 3 Type Circuit Breaker Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB Certification ISO , CE, CCC Width 45mm Rated Operating Current A Ambient Air Temperature -25...+55°C*) Trip Class Class 10A Transport Package Box Trademark JCHKO Origin Zhejiang, China HS Code Production Capacity 5000 Pieces/Week MS116 Low Voltage Motor Protection Circuit Breaker The MS116 series Low Voltage Motor Protection Circuit Breaker is designed for industrial motor control and protection, providing overload, short-circuit, and phase loss protection.

With adjustable rated current from 0.16A to 32A, it is suitable for three-phase motors up to 7.5kW at 400V. Featuring 50kA high breaking capacity and Class 10A tripping characteristic, with temperature compensation from -25℃ to +60℃, it ensures safe motor starting without nuisance tripping..

Product Features - Comprehensive Protection: Thermal-magnetic protection plus phase failure protection for safe motor operation. - High Breaking Capacity: 50kA breaking capacity at 400V for rapid fault clearing. - Temperature Compensation: Stable operation from -25℃ to +60℃ unaffected by ambient temperature.

- Compact Design: 45mm width saves panel space, with lockable handle for safety isolation. Application Environment Suitable for indoor industrial environments at altitudes up to 2000m and ambient temperatures from -25℃ to +60℃.

Specification MS Series Number MS: Thermal-magnetic trip MO: Magnetic-only trip 2 Rated current, trip class and breaking capacity 116-32A, Class 10A (10/16/30/50kA) 132-32A, Class 10A (25/50/100kA) 450-50A, Class 10A (50kA) 451-50A, Class 20A (50kA) 495-100A, Class 10A (50kA) 496-100A, Class 20A (100kA) 497-100A, Class 10A (100kA) 3 Thermal protection setting value Product Features Model MS116 Thermal protection and electromagnetic protection Yes Electromagnetic protection - Phase failure protection Yes Switch position… ON/OFF Magnetic release indication - Lockable handle,no accessories required - Isolation function Yes Width 45mm Rated operating current A Current setting range 0.1...32A Ambient air temperature -25...+55°C*) Technical Parameters Type MS116 MS132 MS165 Thermal and magnetic protection Yes Yes Yes Magnetic protection - - - Phase failure protection Yes Yes Yes Switch position ON/OFF ON/OFF/TRIP ON/OFF/TRIP Magnetic trip indication - Yes Yes Lockable handle, no accessories required - Yes Yes Isolation function Yes Yes Yes Width 45mm 45 mm 55 mm Rated operational current (I e) A 0.16..32A 16...65 A Current setting range 0.1...32 A 0.1...32 A 10...65A Ambient air temperature -25...+55C -25...+60C" -20…+60*C" "Compensated Rated Short-Circuit Breaking Capacity (for 400/415V) Selection Parameters MS116 Motor Rated Power Thermal Trip Setting Range Type Short-Circuit Breaking Capacity Icu Ice 0.03kW 0.1…0.16A MS kA 50 kA 0.06kW 0.16…0.25A MS kA 50 kA 0.09kW 0.25…0.4A MS kA 50 kA 0.18kW 0.4…0.63A MS kA 50kA 0.25kW 0.63…1.0A MS kA 50kA 0.55kW 1.0…1.6A MS kA 50 kA 0.75kW 1.6…2.5A MS kA 50 kA 1.5kW 2.5…4.0A MS kA 50kA 2.2kW 4.0…6.3A MS kA 50kA 4.0kW 6.3...10 A MS kA 50 kA 5.5kW 8…12A MS kA 25 kA 7.5kW 10…16A MS kA 16kA 7.5kW 14...20 A 7.5kW 16…20 A MS kA 10 kA 11kW 18…25A 11kW 20…25A MS kA 10 kA 15kW 25…32A MS kA 10 kA 15kW 23...32A 22kW 30…42A 22kW 40...54 A 30kW 52…65A 1)690V Outline and Installation Dimension Product Dimensions (mm), inches Company Profile FAQ Could I have prices of your produets?

Welcome. Pls feel free to send us an size and Pantone Code of the logo. What's the lead time for regular order? 7-15 days for order quantity Iower than 1000pc;For more quantity,usualy 20 days. Do you inspect the finished products?

Yes,each step of production and fnished products will be came out inspection by QC department before shipping. Packaging & Shipping Packaging Please ., Ltd.

0238 | Applications and Buyer Notes

0238 is organized as a sourcing-ready Power Cables reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions befor

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Power CablesBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Icu
IceBased on visible page data; confirm exact value in the RFQ.
11kW
18…25ABased on visible page data; confirm exact value in the RFQ.
15kW
25…32A MS kA 10 kABased on visible page data; confirm exact value in the RFQ.
22kW
30…42ABased on visible page data; confirm exact value in the RFQ.
30kW
52…65ABased on visible page data; confirm exact value in the RFQ.
Type
MS116 MS132 MS165Based on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryPower Cables
Unitset
IcuIce
11kW18…25A
15kW25…32A MS kA 10 kA
22kW30…42A
30kW52…65A
TypeMS116 MS132 MS165
1.5kW2.5…4.0A MS kA 50kA
2.2kW4.0…6.3A MS kA 50kA
4.0kW6.3...10 A MS kA 50 kA
5.5kW8…12A MS kA 25 kA
7.5kW10…16A MS kA 16kA
ModelMS116
PowerControl & Supply Variable
SpeedNormal Type Circuit Breaker
Width45mm
0.03kW0.1…0.16A MS kA 50 kA
0.06kW0.16…0.25A MS kA 50 kA
0.09kW0.25…0.4A MS kA 50 kA
0.18kW0.4…0.63A MS kA 50kA
0.25kW0.63…1.0A MS kA 50kA
0.55kW1.0…1.6A MS kA 50 kA
0.75kW1.6…2.5A MS kA 50 kA
OriginZhejiang, China
VoltageCircuit Breaker Wholesale Circuit Breaker Case Low
FunctionConventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP
FrequencyDrives
Model NO.MS116
OperationManual Type
PackagingPlease
StructureMCB
TrademarkJCHKO
Trip ClassClass 10A
ApplicationEnvironment Suitable for indoor industrial environments at altitudes up to 2000m and ambient temperatures from-25℃ to +60℃
InstallationFixed
Poles Number3
CertificationISO , CE, CCC
CustomizationAvailable
SpecificationFAQ Packaging & Shipping Overview
US$10 Pieces ( )
Switch positionON/OFF ON/OFF/TRIP ON/OFF/TRIP
Breaking CapacityMotor Protection Circuit Breaker
Motor Rated PowerThermal Trip Setting Range Type Short-Circuit Breaking Capacity
Transport PackageBox
Isolation functionYes
Switch position…ON/OFF
Production Capacity5000 Pieces/Week
Selection ParametersMS116
Current setting range0.1...32A
Ambient Air Temperature25...+55°C*)
Ambient air temperature25...+55°C*)
Rated Operating CurrentA
Rated operating currentA
Arc-extinguishing MediumAir
Magnetic trip indicationYes Yes
Phase failure protectionYes
Rated operational current (I e)A 0.16..32A 16...65 A
Thermal and magnetic protectionYes Yes Yes
Lockable handle, no accessories requiredYes Yes
Thermal protection and electromagnetic protectionYes

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples