0238 Circuit Breaker for Motor Protection Ms116 S | RFQ Sourcing Details
Power Cables · Quote on request
This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.
Product specs
Buyer's Digest
Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Power Cables. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.
Original product description
. Overview Specification Company Profile FAQ Packaging & Shipping Overview . Model NO.
MS116 Speed Normal Type Circuit Breaker Arc-extinguishing Medium Air Installation Fixed Structure MCB Poles Number 3 Type Circuit Breaker Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB Certification ISO , CE, CCC Width 45mm Rated Operating Current A Ambient Air Temperature -25...+55°C*) Trip Class Class 10A Transport Package Box Trademark JCHKO Origin Zhejiang, China HS Code Production Capacity 5000 Pieces/Week MS116 Low Voltage Motor Protection Circuit Breaker The MS116 series Low Voltage Motor Protection Circuit Breaker is designed for industrial motor control and protection, providing overload, short-circuit, and phase loss protection.
With adjustable rated current from 0.16A to 32A, it is suitable for three-phase motors up to 7.5kW at 400V. Featuring 50kA high breaking capacity and Class 10A tripping characteristic, with temperature compensation from -25℃ to +60℃, it ensures safe motor starting without nuisance tripping..
Product Features - Comprehensive Protection: Thermal-magnetic protection plus phase failure protection for safe motor operation. - High Breaking Capacity: 50kA breaking capacity at 400V for rapid fault clearing. - Temperature Compensation: Stable operation from -25℃ to +60℃ unaffected by ambient temperature.
- Compact Design: 45mm width saves panel space, with lockable handle for safety isolation. Application Environment Suitable for indoor industrial environments at altitudes up to 2000m and ambient temperatures from -25℃ to +60℃.
Specification MS Series Number MS: Thermal-magnetic trip MO: Magnetic-only trip 2 Rated current, trip class and breaking capacity 116-32A, Class 10A (10/16/30/50kA) 132-32A, Class 10A (25/50/100kA) 450-50A, Class 10A (50kA) 451-50A, Class 20A (50kA) 495-100A, Class 10A (50kA) 496-100A, Class 20A (100kA) 497-100A, Class 10A (100kA) 3 Thermal protection setting value Product Features Model MS116 Thermal protection and electromagnetic protection Yes Electromagnetic protection - Phase failure protection Yes Switch position… ON/OFF Magnetic release indication - Lockable handle,no accessories required - Isolation function Yes Width 45mm Rated operating current A Current setting range 0.1...32A Ambient air temperature -25...+55°C*) Technical Parameters Type MS116 MS132 MS165 Thermal and magnetic protection Yes Yes Yes Magnetic protection - - - Phase failure protection Yes Yes Yes Switch position ON/OFF ON/OFF/TRIP ON/OFF/TRIP Magnetic trip indication - Yes Yes Lockable handle, no accessories required - Yes Yes Isolation function Yes Yes Yes Width 45mm 45 mm 55 mm Rated operational current (I e) A 0.16..32A 16...65 A Current setting range 0.1...32 A 0.1...32 A 10...65A Ambient air temperature -25...+55C -25...+60C" -20…+60*C" "Compensated Rated Short-Circuit Breaking Capacity (for 400/415V) Selection Parameters MS116 Motor Rated Power Thermal Trip Setting Range Type Short-Circuit Breaking Capacity Icu Ice 0.03kW 0.1…0.16A MS kA 50 kA 0.06kW 0.16…0.25A MS kA 50 kA 0.09kW 0.25…0.4A MS kA 50 kA 0.18kW 0.4…0.63A MS kA 50kA 0.25kW 0.63…1.0A MS kA 50kA 0.55kW 1.0…1.6A MS kA 50 kA 0.75kW 1.6…2.5A MS kA 50 kA 1.5kW 2.5…4.0A MS kA 50kA 2.2kW 4.0…6.3A MS kA 50kA 4.0kW 6.3...10 A MS kA 50 kA 5.5kW 8…12A MS kA 25 kA 7.5kW 10…16A MS kA 16kA 7.5kW 14...20 A 7.5kW 16…20 A MS kA 10 kA 11kW 18…25A 11kW 20…25A MS kA 10 kA 15kW 25…32A MS kA 10 kA 15kW 23...32A 22kW 30…42A 22kW 40...54 A 30kW 52…65A 1)690V Outline and Installation Dimension Product Dimensions (mm), inches Company Profile FAQ Could I have prices of your produets?
Welcome. Pls feel free to send us an size and Pantone Code of the logo. What's the lead time for regular order? 7-15 days for order quantity Iower than 1000pc;For more quantity,usualy 20 days. Do you inspect the finished products?
Yes,each step of production and fnished products will be came out inspection by QC department before shipping. Packaging & Shipping Packaging Please ., Ltd.
0238 | Applications and Buyer Notes
0238 is organized as a sourcing-ready Power Cables reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions befor
Applications
- Initial shortlist building for related product or supplier options.
- Specification and application fit review before bulk purchasing.
- Category, keyword and detail-page comparison before sending an RFQ.
Key specifications
- Category
- Power CablesBased on visible page data; confirm exact value in the RFQ.
- Unit
- setBased on visible page data; confirm exact value in the RFQ.
- Icu
- IceBased on visible page data; confirm exact value in the RFQ.
- 11kW
- 18…25ABased on visible page data; confirm exact value in the RFQ.
- 15kW
- 25…32A MS kA 10 kABased on visible page data; confirm exact value in the RFQ.
- 22kW
- 30…42ABased on visible page data; confirm exact value in the RFQ.
- 30kW
- 52…65ABased on visible page data; confirm exact value in the RFQ.
- Type
- MS116 MS132 MS165Based on visible page data; confirm exact value in the RFQ.
Buyer tips
- State quantity range and split-delivery needs before price comparison.
- Add certification, material or inspection standards when they affect acceptance.
- For time-sensitive projects, include target arrival date and destination.
- For special applications, describe operating condition, installation environment and duty cycle.
FAQ
What should buyers confirm first?
Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.
Can buyers inquire when specs are incomplete?
Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.
How should this listing be evaluated?
Check title, category, specifications and related keywords against the actual sourcing requirement.
Source mix: ugc
Key specifications
Product sourcing keywords
These terms come from the title, visible copy and specifications, and link into matching aggregate pages.
Continue from this detail page into sourcing structure
These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.
This URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 1 0 Sqmm Dual Core Copper Flexible House Wiring Cable At Best Price In BengaluruThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Procurement sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cables Busbar And Accessories categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Meters And Protection Devices categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Switchgear And Breakers categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Transformers And Substation Equipment categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path CompanyThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 100kva 10kv Cast Resin Dry Type Transformer Ul Certified 10kv Cast Resin And Ul CertifiedThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 100kva 10kv Dry Type Transformer For Solar Power Systems 100kva And Solar Power SystemsThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 10kv Power Supply Ring Main Unit Cable Accessories Ceramic Metal Silicone Rubber Epoxy Resin BushingThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 11kv 12kv 20kv 24kv Electrical Power Transmission Medium Voltage Air Insulated SwitchgearThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 11kv 12kv Medium Voltage Sis Solid Insulation Compact Modular SwitchgearThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 126kv 1250a Dry Resin Impregnated Fiber Transformer BushingThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
PowerGridSource related sourcing paths
Medium Voltage Distribution Projects
PowerGridSource procurement phrases
PowerGridSource related product samples
The residual current transformer is mainly used to detect all devices in the distribution circuit that pass through the ...
Meters and Protection Devices Energy Meter Split Core Current Transformer 1: 1000 Ratio - Current Transformer and Energy Meter CurSplit core current transformer LMZK1-10 series LMZK series split-core current transformers are suitable for the current ...
Meters and Protection Devices Advanced Electricity Smart Meter with 1: 1000 Ratio Transformer - Electricity Transformer and SmartThe residual current transformer is mainly used to detect all devices in the distribution circuit that pass through the ...
Meters and Protection Devices 6-Phase Relay Protection Test Equipment with Current Injectional Method for Substation MaintanenceDJB-426 6 Phase Relay Test Kit-199 "microcomputer relay protection test device technology", list
Meters and Protection Devices High-Performance Outdoor Vacuum Circuit Breaker for 11kv 33kv Systems - Outdoor Circuit Breaker andOutdoor Vacuum Circuit Breaker for 11kV 33kV Power Distribution Reliable Outdoor Protection Solution for Utility Power S...
Meters and Protection Devices Integrated Cable Fault Locator System - Cable Fault Locator and Power Cable Fault LocatorMeasure the power cable of different sections, different media of various materials, Coaxial cable, Street light cables ...