PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
6-Phase Relay Protection Test Equipment with Current Injectional Method for Substation Maintanence
Transformers And Substation Equipment

6-Phase Relay Protection Test Equipment with Curr | RFQ Sourcing Details

Transformers And Substation Equipment · 110V/2A, 220V/1A Timing Measurement Parameter · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryTransformers and Substation Equipment
Unitset
PowerRequirements Parameter
Weight30kg
VoltageAC220V±10%
Capacity110V/2A, 220V/1A Timing Measurement Parameter
FeaturesSatisfy all on-site test requirements. Technical indicators fully meet the DL/T624-1997 "microcomputer relay protection test device technology"
Frequency50/60Hz Current Rating 10A
CategoryTransformers And Substation Equipment
AvailabilityInquiry required
Source date2026-06-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Transformers And Substation Equipment. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

DJB-426 6 Phase Relay Test Kit (With GPS) DJB series microcomputer relay protection tester is a new small microcomputer relay protection testing instrument, manufactured referencing DL/T624-199 "microcomputer relay protection test device technology", listening to the views of users, summarizing the advantages and disadvantages of the same domestic products, using modern advanced microelectronic technology and device.

Features: Satisfy all on-site test requirements. Technical indicators fully meet the DL/T624-1997 "microcomputer relay protection test device technology" standard issued by the Ministry of electric power. This device Windows XP system with recovery function, avoid system crash caused by the illegal shutdown or misuse.

Main control board uses DSF+FPGA structure, 16 bit DAC output, the basic wave can produce weekly 2000 points of high density sine wave, greatly improve the waveform quality, and improve the accuracy of the test instrument.

The classic Windows XP operation interface, the man-machine interface is friendly, the operation is simple and quick. Amplifier using high fidelity linear power amplifier, both to ensure the accuracy of the small current, but also to ensure the stability of the large current. With GPS synchronous test function.

The device can be built in GPS synchronous card, connected with the PC machine through the RS232 interface, to achieve synchronous test switch of two test sets in different places.

Specification AC Current Source Parameter Specification Current Range 3×(0-30A)/phase, accuracy 0.5% 6-phase Parallel Output 180A Continuous Working Current 10A Output Power 300VA/phase Maximum 6-phase Output Power 900VA Maximum 6-phase Operation Time 10s Frequency Range 0-1000. Hz, accuracy 0.001.

Hz Harmonics 2-20 orders, phase 0-360°, accuracy 0.1° DC Current Source Parameter Specification Current Range 20A/phase, accuracy 0.5% Output Power 300VA/phase AC Voltage Source Parameter Specification Phase Voltage Output 6×(0-125V)/phase, accuracy 0.5% Line Voltage Output 0-250V Output Power 70VA (phase)/100VA (line) Frequency Range 0-1000.

Hz, accuracy 0.001.

Hz Harmonics 2-20 orders, phase 0-360°, accuracy 0.1° DC Voltage Source Parameter Specification Phase Voltage Range 0-±150V, accuracy 0.5% Line Voltage Range 0-±300V Output Power 90VA (phase)/180VA (line) Digital I/O Parameter Specification Input Channels 8 pairs, dry , internal 24V active output Logic Threshold 0-6V DC (low), 15-250V DC (high) Output Channels 4 pairs, dry , 220V/1A Timing Measurement Parameter Specification Range 1ms-9999s Accuracy 1ms Physical Specifications Parameter Specification Dimensions 455×530×220mm (W×H×D) Weight 30kg Power Requirements Parameter Specification Supply Voltage AC220V±10% Frequency 50/60.

Hz Current Rating 10A

6-Phase | Applications and Buyer Notes

6-Phase is organized as a sourcing-ready Transformers And Substation Equipment reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements a

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Transformers and Substation EquipmentBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Power
Requirements ParameterBased on visible page data; confirm exact value in the RFQ.
Weight
30kgBased on visible page data; confirm exact value in the RFQ.
Voltage
AC220V±10%Based on visible page data; confirm exact value in the RFQ.
Capacity
110V/2A, 220V/1A Timing Measurement ParameterBased on visible page data; confirm exact value in the RFQ.
Features
Satisfy all on-site test requirements. Technical indicators fully meet the DL/T6Based on visible page data; confirm exact value in the RFQ.
Frequency
50/60Hz Current Rating 10ABased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryTransformers and Substation Equipment
Unitset
PowerRequirements Parameter
Weight30kg
VoltageAC220V±10%
Capacity110V/2A, 220V/1A Timing Measurement Parameter
FeaturesSatisfy all on-site test requirements. Technical indicators fully meet the DL/T624-1997 "microcomputer relay protection test device technology"
Frequency50/60Hz Current Rating 10A
interfaceis friendly, the operation is simple and quick. Amplifier using high fidelity linear
SpecificationSupply
SpecificationsParameter

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples

Supplier profile

PowerGridSource Imported Supplier Pool
主营:Transformers and Substation Equipment

View full profile >