PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
12kv AC Vacuum
Vacuum Circuit Breakers

12kv AC Vacuum | RFQ Sourcing Details

Vacuum Circuit Breakers · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryVacuum Circuit Breakers
Unitset
CategoryVacuum Circuit Breakers
AvailabilityInquiry required
Updated2026-05-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Vacuum Circuit Breakers. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Our Advantages A. 25 years experience of production Medium voltage material B. 18 years for overseas market;you no worry for communication and save time C. IEC CNAS standard testing lab inside own property factory industrial zone D. Big Brand t rusted material supplier, you no worry for quality control E.

Quality control 3 times 100% inspection testing from raw material to finished Special 3-pole and 4-pole high-voltage vacuum . After installing a mechanical interlock shaft between two vacuum , mechanical interlocking can be achieved, and electrical interlocking can also be realized. A 5-pole high-voltage vacuum .

After installing a mechanical interlock shaft between two vacuum , mechanical interlocking can be achieved, and electrical interlocking can also be realized, providing dual safety protection for phase reversal. The above-mentioned high-voltage vacuum .

They are capable of frequent operation and offer advantages such as long mechanical life, high reliability, low failure rate, and strong breaking performance.

Name Unit Parameter Rated voltage kV 12 Rated current A 160 , 250 , 400 , 630 Power frequency withstand voltage kV 42 Lightning impulse withstand voltage kV 75 The rated breaking capacity A 8. Ie 25 times The rated closing capacity A 10. Ie 100 times Rated short-time resistance current kA 10.

Ie 1.6 , 2.5 , 4 , 6.3 Rated current peak tolerance kA 25. Ie 4 , 6.3 , 10 , 16 Short circuit current breaking and closing A 10. Ie O-180s-CO-180s-CO 1 times Overload withstand current kA 15.

Ie 2.4 , 3.8 , 6 ,10 The rated .5±0.5 Overtravel mm ≥1.5 Closing synchronism ms ≤2 Mechanical life Ten thousand times 50 Electrical life AC3 Ten thousand times 25 AC4 Ten thousand times 10 Company Profile 1 of the best Medium Voltage material for power transmission and distribution private company in China Quality control: 3 times 100% inspection testing 1.

Raw Material Inspection 2. Production Line 3. Production Line and Testing 4. Test equipment as IEC standard Power frequency testing: 100% according to IEC standards;Big current testing temperature rising equipment: provide up to 3000A;Partial discharge testing room: provides two different size for vacuum

12kv | Applications and Buyer Notes

12kv is organized as a sourcing-ready Vacuum Circuit Breakers reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time ques

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Vacuum Circuit BreakersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryVacuum Circuit Breakers
Unitset

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

Related applications PowerGridSource related paths

Industrial Power Distribution

Renewable Integration and Storage

Related solutions PowerGridSource related paths

Medium Voltage Distribution Projects

Energy Metering and Protection Upgrades

PowerGridSource procurement phrases

PowerGridSource related product samples