PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
500 kVA Epoxy Resin Cast Dry-Type Power Transformer, Configurable up to 35 kV
Dry Type Transformers

500 kVA Epoxy Resin Cast Dry-Type Power Transform | RFQ Sourcing Details

Dry Type Transformers · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryDry Type Transformers
Unitset
Core shapeRing
InstallationOutdoor or inside a substation
Package size160 × 140 × 150 cm
CustomizationAvailable
Model optionsSCB10, SCB11, SCB12, SCB13 and SCB15
Rated capacity500 kVA
CategoryDry Type Transformers
AvailabilityInquiry required
Source date2026-07-23

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Dry Type Transformers. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

Product overview This 500 kVA dry-type power transformer uses an oil-free, epoxy-resin-encapsulated design and a two-winding, core-type construction. It is intended for power and distribution duties and may be configured for installation outdoors or inside a substation.

Heat dissipation is Supported configuration options Available model families are listed as SCB10, SCB11, SCB12, SCB13 and SCB15. Listed high-voltage selections include 6, 6.3, 10, 10.5, 11, 20, 25, 33 and 35 kV. Listed low-voltage selections include 400 V, 415 V and 0.4 kV.

Configuration can be adapted to local system requirements. The oil-free construction eliminates insulating-oil leakage and removes the need for oil-quality testing. The epoxy-resin encapsulation is described as providing resistance to moisture, dust and corrosion, together with flame-retardant properties.

The stated maximum application range is medium-to-low-voltage distribution service up to 35 kV rather than ultra-high-voltage transmission.

Procurement questions to confirm Before ordering, the buyer should confirm the required model, rated capacity, primary and secondary voltages, frequency, vector group, tap range, impedance, insulation level and cooling mode.

Also confirm whether the installation is indoor or outdoor and specify the site altitude, ambient temperature, humidity, pollution level, enclosure or protection requirements, available ventilation and acceptable sound limit.

Request confirmation of the exact dimensions, total installed weight, terminal arrangement, accessory scope, applicable certification documents, routine and type-test reports, drawings, installation clearances and maintenance requirements for the selected configuration.

500 | Applications and Buyer Notes

500 is organized as a sourcing-ready Dry Type Transformers reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questio

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Dry Type TransformersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Core shape
RingBased on visible page data; confirm exact value in the RFQ.
Installation
Outdoor or inside a substationBased on visible page data; confirm exact value in the RFQ.
Package size
160 × 140 × 150 cmBased on visible page data; confirm exact value in the RFQ.
Customization
AvailableBased on visible page data; confirm exact value in the RFQ.
Model options
SCB10, SCB11, SCB12, SCB13 and SCB15Based on visible page data; confirm exact value in the RFQ.
Rated capacity
500 kVABased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryDry Type Transformers
Unitset
Core shapeRing
InstallationOutdoor or inside a substation
Package size160 × 140 × 150 cm
CustomizationAvailable
Model optionsSCB10, SCB11, SCB12, SCB13 and SCB15
Rated capacity500 kVA
Housing materialEpoxy resin
Insulation systemEpoxy-resin encapsulated windings
Transport packageWooden package
Package gross weight300 kg
Listed certificationsISO 9001:2000, ISO 9001 and CCC
Frequency characteristicPower frequency
Listed low-voltage options400 V, 415 V and 0.4 kV
Listed high-voltage options6, 6.3, 10, 10.5, 11, 20, 25, 33 and 35 kV

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples

Supplier profile

PowerGridSource Imported Supplier Pool
主营:Distribution Transformers

View full profile >