PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
Automatic Transformer Oil Breakdown Voltage Bdv Tester Oil Dielectric Strength Tester - Breakdown Vo
Voltage Transformers

Automatic Transformer Oil Breakdown Voltage Bdv T | RFQ Sourcing Details

Voltage Transformers · 1.5KVA 11 · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryVoltage Transformers
Unitset
Size4 1 0×3 9 0× 38 0mm 3 1 5
powersupply: AC 220V± 2 0% 50/60Hz 2 Output
voltagedanger. Accessories Sr no Description Qty 1 Oil cup 1 2
Capacity1.5KVA 11
Standardgauge 1 4 Magnon 2 5 Tweezer 1 6 Earth wire 1 7 Fuse (3A) 2 8 Print paper 1 9 Factory's calibration 1 10 Operating manual 1
CategoryVoltage Transformers
AvailabilityInquiry required
Source date2026-06-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Voltage Transformers. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

General introduction Y J J- 6 01 A (80KV) & YJJ-601B (100KV) is new developed according to the national standard GB 507-2002 and IEC60156 (IEC156) Insulating Oil Dielectric Strength Testing Method . LCD screen can display test procedure and test result.

All the human interaction operations complete by the rotating mouse .It is very easy for customers to measure the breakdown voltage. It can print the test result. The instrument is easy to operate and it has beautiful appearance , high measurement accuracy, strong anti-interference ability, it is safe and reliable.

Advantage 1.The instrument is controlled by large-capacity single-chip microcomputer, and it's stable and reliable;2.

Built-in wide range of watchdog circuits to avoid the phenomenon of crashes;3.Various operation options, the instrument program has two national standard methods and custom operation of GB507-1986 and GB507-2002, IEC156 4.

O il cup is cast in one time with special glass to prevent the occurrence of interference such as oil leakage;5.The unique high-voltage sampling design allows the test value to directly enter the A/D converter, avoiding the error caused in the analog circuit and making the measurement result more accurate;6.The instrument has functions such as overcurrent, overvoltage and short circuit protection, strong anti-interference ability and good electromagnetic compatibility;7.

Portable structure, easy to move, easy to use indoors and outdoors . 8.RS232 interface. Technique index 1 Rated power supply: AC 220V± 2 0% 50/60. Hz 2 Output voltage: YJJ-601A: AC 0~80KV or YJJ-601B: AC 0~100KV 3 Rate of voltage rise: 0.5 KV/ S -5.

0KV/S (step 0.5KV/s), error: 0.2KV/S 4 Measuring accuracy : 2%+2digits 5.Power distortion rate: < 1% 6.Electrode gap:standard 2.5mm 7. Times of withstand voltage : for option) 8. Stirring time: 15S (0-99S for option) 9. Stewing time: 900S (0-5900S for option) 10. Capacity: 1.5KVA 11. Power < 200W 1 2.

Environment temperatures: 0 -40ºC 1 3. Relative humidity: ≤8 5 %RH 1 4. Size: 4 1 0×3 9 0× 38 0mm 3 1 5. Weight: 2 6 kg Panel Instruction 1. LCD : displays date, time, operating parameters, test result s , operation menu prompts and other related information;2. Function key : Select to set operating parameters;3.

P rinter :it prints the test results;4. Changing Switch : select different boost rate : 2KV/s or 3KV/s;5. I ndicator : it means that the relevant operation steps are in progress when it is light;6. Oil cup protection cover: put or remove oil cup after open it , it is allowed to test when closed.

7.Temperature and humidity sensor : it measures Celsius temperature and relative humidity and display;8. Ground : good grounding is necessary;9. P ower & switch: AC220V 50H z 10. Open/close button: Press the switch to open or close the box cover 11. Mark of high voltage danger.

Accessories Sr no Description Qty 1 Oil cup 1 2 Power supply cable 1 3 Standard gauge 1 4 Magnon 2 5 Tweezer 1 6 Earth wire 1 7 Fuse (3A) 2 8 Print paper 1 9 Factory's calibration 1 10 Operating manual 1

Automatic | Applications and Buyer Notes

Automatic is organized as a sourcing-ready Voltage Transformers reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time qu

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Voltage TransformersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Size
4 1 0×3 9 0× 38 0mm 3 1 5Based on visible page data; confirm exact value in the RFQ.
power
supply: AC 220V± 2 0% 50/60Hz 2 OutputBased on visible page data; confirm exact value in the RFQ.
voltage
danger. Accessories Sr no Description Qty 1 Oil cup 1 2Based on visible page data; confirm exact value in the RFQ.
Capacity
1.5KVA 11Based on visible page data; confirm exact value in the RFQ.
Standard
gauge 1 4 Magnon 2 5 Tweezer 1 6 Earth wire 1 7 Fuse (3A) 2 8 Print paper 1 9 FaBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryVoltage Transformers
Unitset
Size4 1 0×3 9 0× 38 0mm 3 1 5
powersupply: AC 220V± 2 0% 50/60Hz 2 Output
voltagedanger. Accessories Sr no Description Qty 1 Oil cup 1 2
Capacity1.5KVA 11
Standardgauge 1 4 Magnon 2 5 Tweezer 1 6 Earth wire 1 7 Fuse (3A) 2 8 Print paper 1 9 Factory's calibration 1 10 Operating manual 1

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

Related applications PowerGridSource related paths

Industrial Power Distribution

Renewable Integration and Storage

Related solutions PowerGridSource related paths

Energy Metering and Protection Upgrades

Medium Voltage Distribution Projects

PowerGridSource procurement phrases

PowerGridSource related product samples

Supplier profile

PowerGridSource Imported Supplier Pool
主营:Voltage Transformers

View full profile >