Automatic Transformer Oil Breakdown Voltage Bdv T | RFQ Sourcing Details
Voltage Transformers · 1.5KVA 11 · Quote on request
This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.
Product specs
Buyer's Digest
Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Voltage Transformers. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.
Original product description
General introduction Y J J- 6 01 A (80KV) & YJJ-601B (100KV) is new developed according to the national standard GB 507-2002 and IEC60156 (IEC156) Insulating Oil Dielectric Strength Testing Method . LCD screen can display test procedure and test result.
All the human interaction operations complete by the rotating mouse .It is very easy for customers to measure the breakdown voltage. It can print the test result. The instrument is easy to operate and it has beautiful appearance , high measurement accuracy, strong anti-interference ability, it is safe and reliable.
Advantage 1.The instrument is controlled by large-capacity single-chip microcomputer, and it's stable and reliable;2.
Built-in wide range of watchdog circuits to avoid the phenomenon of crashes;3.Various operation options, the instrument program has two national standard methods and custom operation of GB507-1986 and GB507-2002, IEC156 4.
O il cup is cast in one time with special glass to prevent the occurrence of interference such as oil leakage;5.The unique high-voltage sampling design allows the test value to directly enter the A/D converter, avoiding the error caused in the analog circuit and making the measurement result more accurate;6.The instrument has functions such as overcurrent, overvoltage and short circuit protection, strong anti-interference ability and good electromagnetic compatibility;7.
Portable structure, easy to move, easy to use indoors and outdoors . 8.RS232 interface. Technique index 1 Rated power supply: AC 220V± 2 0% 50/60. Hz 2 Output voltage: YJJ-601A: AC 0~80KV or YJJ-601B: AC 0~100KV 3 Rate of voltage rise: 0.5 KV/ S -5.
0KV/S (step 0.5KV/s), error: 0.2KV/S 4 Measuring accuracy : 2%+2digits 5.Power distortion rate: < 1% 6.Electrode gap:standard 2.5mm 7. Times of withstand voltage : for option) 8. Stirring time: 15S (0-99S for option) 9. Stewing time: 900S (0-5900S for option) 10. Capacity: 1.5KVA 11. Power < 200W 1 2.
Environment temperatures: 0 -40ºC 1 3. Relative humidity: ≤8 5 %RH 1 4. Size: 4 1 0×3 9 0× 38 0mm 3 1 5. Weight: 2 6 kg Panel Instruction 1. LCD : displays date, time, operating parameters, test result s , operation menu prompts and other related information;2. Function key : Select to set operating parameters;3.
P rinter :it prints the test results;4. Changing Switch : select different boost rate : 2KV/s or 3KV/s;5. I ndicator : it means that the relevant operation steps are in progress when it is light;6. Oil cup protection cover: put or remove oil cup after open it , it is allowed to test when closed.
7.Temperature and humidity sensor : it measures Celsius temperature and relative humidity and display;8. Ground : good grounding is necessary;9. P ower & switch: AC220V 50H z 10. Open/close button: Press the switch to open or close the box cover 11. Mark of high voltage danger.
Accessories Sr no Description Qty 1 Oil cup 1 2 Power supply cable 1 3 Standard gauge 1 4 Magnon 2 5 Tweezer 1 6 Earth wire 1 7 Fuse (3A) 2 8 Print paper 1 9 Factory's calibration 1 10 Operating manual 1
Automatic | Applications and Buyer Notes
Automatic is organized as a sourcing-ready Voltage Transformers reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time qu
Applications
- Initial shortlist building for related product or supplier options.
- Specification and application fit review before bulk purchasing.
- Category, keyword and detail-page comparison before sending an RFQ.
Key specifications
- Category
- Voltage TransformersBased on visible page data; confirm exact value in the RFQ.
- Unit
- setBased on visible page data; confirm exact value in the RFQ.
- Size
- 4 1 0×3 9 0× 38 0mm 3 1 5Based on visible page data; confirm exact value in the RFQ.
- power
- supply: AC 220V± 2 0% 50/60Hz 2 OutputBased on visible page data; confirm exact value in the RFQ.
- voltage
- danger. Accessories Sr no Description Qty 1 Oil cup 1 2Based on visible page data; confirm exact value in the RFQ.
- Capacity
- 1.5KVA 11Based on visible page data; confirm exact value in the RFQ.
- Standard
- gauge 1 4 Magnon 2 5 Tweezer 1 6 Earth wire 1 7 Fuse (3A) 2 8 Print paper 1 9 FaBased on visible page data; confirm exact value in the RFQ.
Buyer tips
- State quantity range and split-delivery needs before price comparison.
- Add certification, material or inspection standards when they affect acceptance.
- For time-sensitive projects, include target arrival date and destination.
- For special applications, describe operating condition, installation environment and duty cycle.
FAQ
What should buyers confirm first?
Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.
Can buyers inquire when specs are incomplete?
Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.
How should this listing be evaluated?
Check title, category, specifications and related keywords against the actual sourcing requirement.
Source mix: ugc
Key specifications
Product sourcing keywords
These terms come from the title, visible copy and specifications, and link into matching aggregate pages.
Continue from this detail page into sourcing structure
These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.
This URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 100kva 10kv Dry Type Transformer For Solar Power Systems 100kva And Solar Power SystemsThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 10kv Epoxy Resin Indoor Electric Single Phase Potential Transformer PtThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 10kv Power Supply Ring Main Unit Cable Accessories Ceramic Metal Silicone Rubber Epoxy Resin BushingThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 10p10 500 5a Split Core Ct Current TransformerThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 11kv 12kv 20kv 24kv Electrical Power Transmission Medium Voltage Air Insulated SwitchgearThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 11kv 12kv Medium Voltage Distribution Air Insulated SwitchgearThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 11kv 12kv Medium Voltage Sis Solid Insulation Compact Modular SwitchgearThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 150kva 20kv Dry Type Transformer With Low Loss Ce Low Loss And CeThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 23kv Oil Filled Ansi Standard Power Transformer Bay O Net B O N Inline Link Auto Electrical ThermaThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cables Busbar And Accessories categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Meters And Protection Devices categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Switchgear And Breakers categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Transformers And Substation Equipment categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
PowerGridSource related sourcing paths
PowerGridSource procurement phrases
PowerGridSource related product samples
The residual current transformer is mainly used to detect all devices in the distribution circuit that pass through the ...
Meters and Protection Devices Energy Meter Split Core Current Transformer 1: 1000 Ratio - Current Transformer and Energy Meter CurSplit core current transformer LMZK1-10 series LMZK series split-core current transformers are suitable for the current ...
Meters and Protection Devices Advanced Electricity Smart Meter with 1: 1000 Ratio Transformer - Electricity Transformer and SmartThe residual current transformer is mainly used to detect all devices in the distribution circuit that pass through the ...
Meters and Protection Devices 6-Phase Relay Protection Test Equipment with Current Injectional Method for Substation MaintanenceDJB-426 6 Phase Relay Test Kit-199 "microcomputer relay protection test device technology", list
Meters and Protection Devices High-Performance Outdoor Vacuum Circuit Breaker for 11kv 33kv Systems - Outdoor Circuit Breaker andOutdoor Vacuum Circuit Breaker for 11kV 33kV Power Distribution Reliable Outdoor Protection Solution for Utility Power S...
Meters and Protection Devices Integrated Cable Fault Locator System - Cable Fault Locator and Power Cable Fault LocatorMeasure the power cable of different sections, different media of various materials, Coaxial cable, Street light cables ...