PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
Portable Sf6 Gas Tester
Harmonic Filters

Portable Sf6 Gas Tester | RFQ Sourcing Details

Harmonic Filters · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryHarmonic Filters
Unitset
CategoryHarmonic Filters
AvailabilityInquiry required
Updated2026-05-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Harmonic Filters. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

sf6 gas comprenhensive tester Brief Introduction SF6 comprehensive analyzer is specially used for index detection of insulating gas in SF6 electrical equipment, and adopts the high-performance sensor for measurement of dew point, purity and decomposition product to guarantee the accurate and stable test results.

Equipped with the unique gas circuit structure, it adopts the high-precision electronic flowmeter for full-automatic detection so that the SF6 can be more accurate in gas analysis.

Three indexes can be detected via one-time measurement, which greatly reduces the workload of users and improves the work efficiency Feature Dual-channel flow control design without fear of pressure fluctuation Utilization þ f high-precision electronic flowmeter, with flow overruns prompt Switch of trends of measuring objects, and real-time display of data .Self-calibration function of zero and slope after startup Crossing-resistance interference technology of sensor Cleaning of residual gas in air circuit Lithium battery with ultra-large capacity, and dual purpose of AC / DC Large-capacity data storage, and USDB one-key data export Thermosensitive mute printer for rapid printing on the scene Parameter SF6 gas decomposition product detection module Measurement scope [SO 2 ]0 ~ 100 µl/l , [H 2 S]0 ~ 100 µl/l , [CO]0 ~ 1000 µl/l Precision SO2, H2S: ±0.5µl/l if measurement value ≤10 µl/l;±5% if measurement value > 10 µl/l CO: ±2.0 if measurement value ≤50 µl/l ±4% if measurement value > 50 µl/l Repeatability SO2, H2S: ±0.2 µl/l if measurement value ≤10 µl/l;±2% if measurement value > 10 µl/l CO: ±1.5 µl/l if measurement value ≤50 µl/l;±3% if measurement value > 50 µl/l Resolution SO2, H2S, CO: 0.1 µl/l Response time ≤30s SF6 purity detection module Measurement scope 0 ~ 100% Precision ≤±0.5% (90 ~ 100%:≤±0.2%) Repeatability ≤±0.2% Resolution 0.01% Response time ≤30S SF6 humidity detection module Dew point range ―80 ºC ~ +20 ºC Measurement accuracy ±0.5 ºC Micro-water scope 0.05 ~ 23100 μL/L Measurement response time (+20 ºC ) -60 ºC → 20 ºC 5S[10s] 20 ºC → -60 ºC 10S[300S] Resolution Dew point: 0.1 ºC Micro-water: 0.1ppm (100ppm ~ 1000ppm) 0.01ppm(10ppm ~ 100ppm) Repetition: ±0.2ºC Flow regulation 1: 0.2L/min;Flow regulation: 2:0.5-0.6L/min Parameters of whole machine Charging source 220VAC±10% 50HZ Battery Lithium battery 12V 17.5AH Service time > 10h Display screen 7-in

Portable | Applications and Buyer Notes

Portable is organized as a sourcing-ready Harmonic Filters reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questio

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Harmonic FiltersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryHarmonic Filters
Unitset

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

Related applications PowerGridSource related paths

Renewable Integration and Storage

Related solutions PowerGridSource related paths

Energy Metering and Protection Upgrades

PowerGridSource procurement phrases

PowerGridSource related product samples