PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
SB-500/10.5 Three-Phase Oil-Immersed Distribution Transformer
Transformers And Substation Equipment

SB-500/10.5 Three-Phase Oil-Immersed Distribution | RFQ Sourcing Details

Transformers And Substation Equipment · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryTransformers and Substation Equipment
Unitset
ModelSB-500/10.5
Transformer typeThree-phase, two-winding, oil-immersed distribution transformer
Tap range options±2 × 2.5% or ±5%
Low-voltage rating0.4 kV
High-voltage options6, 6.3, 6.6, 10, 10.5, or 11 kV
Rated capacity range30–2,500 kVA
CategoryTransformers And Substation Equipment
AvailabilityInquiry required
Source date2026-07-20

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Transformers And Substation Equipment. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

The SB-500/10.5 is a three-phase, core-type, two-winding oil-immersed transformer intended for power and distribution transformer duties. The stated configuration uses transformer oil as its principal insulation and cooling medium.

Listed cooling approaches include oil-immersed self-cooling, oil-immersed air cooling, and forced oil circulation. The published series covers rated capacities from 30 to 2,500 kVA. Listed high-voltage selections are 6, 6.3, 6.6, 10, 10.5, and 11 kV, with a stated low-voltage rating of 0.4 kV.

Available tap ranges are ±2 × 2.5% and ±5%, while listed connection-group options include Dyn11, Yzn11, and Yyn0. The product information identifies a power-frequency design and an M-shaped core.

It also describes major assemblies such as the core, windings, oil tank, voltage-regulating device, radiator, oil reservoir, gas relay, insulation bushings, and pressure-relief or explosion-protection components.

Published normal-service conditions specify installation below 1,000 m elevation, a maximum ambient temperature of +40°C, a maximum daily average of +30°C, a maximum annual average of +20°C, and a minimum outdoor temperature of -25°C.

Applications outside these conditions should be treated as special-service installations and reviewed before configuration approval. Performance values vary by capacity and selected design.

The supplied table lists no-load loss from 33 W to 860 W, no-load current from 1.5% to 0.2%, and impedance voltage values of 4%, 4.5%, or 5% across the series.

Because the source also presents separate example performance figures that do not map clearly to every rating, buyers should request a model-specific guaranteed data sheet rather than applying a single efficiency or loss value to the entire range.

Before procurement, confirm the required transformer model and capacity, primary and secondary voltages, tap range, connection group, circuit wiring scheme, cooling arrangement, and any special electrical-component requirements.

Also confirm the applicable standards and certificates for the exact supplied unit, dimensional drawing, terminal arrangement, accessory scope, protection devices, spare-parts list, test documentation, installation environment, packaging, and warranty terms.

These project-specific items should be recorded in the approved technical schedule before manufacture.

SB-500 | Applications and Buyer Notes

SB-500 is organized as a sourcing-ready Transformers And Substation Equipment reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements an

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Transformers and Substation EquipmentBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Model
SB-500/10.5Based on visible page data; confirm exact value in the RFQ.
Transformer type
Three-phase, two-winding, oil-immersed distribution transformerBased on visible page data; confirm exact value in the RFQ.
Tap range options
±2 × 2.5% or ±5%Based on visible page data; confirm exact value in the RFQ.
Low-voltage rating
0.4 kVBased on visible page data; confirm exact value in the RFQ.
High-voltage options
6, 6.3, 6.6, 10, 10.5, or 11 kVBased on visible page data; confirm exact value in the RFQ.
Rated capacity range
30–2,500 kVABased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryTransformers and Substation Equipment
Unitset
ModelSB-500/10.5
Transformer typeThree-phase, two-winding, oil-immersed distribution transformer
Tap range options±2 × 2.5% or ±5%
Low-voltage rating0.4 kV
High-voltage options6, 6.3, 6.6, 10, 10.5, or 11 kV
Rated capacity range30–2,500 kVA
Connection-group optionsDyn11, Yzn11, or Yyn0
Frequency characteristicPower frequency
Listed impedance voltage4%, 4.5%, or 5%, depending on capacity
Listed transport packingWooden packed
Normal-service elevationBelow 1,000 m
Cooling methods describedOil-immersed self-c ing, oil-immersed air c ing, or forced oil circulation
Listed no-load loss range33–860 W, depending on capacity
Listed package dimensions2,800 × 2,200 × 2,400 cm;buyer should verify this listing value before ordering
Listed no-load current range0.2%–1.5%, depending on capacity
Normal-service ambient limitsMaximum +40°C;maximum daily average +30°C;maximum annual average +20°C;minimum outdoor temperature-25°C
Listed specification dimensions3,600 × 2,200 × 2,400 mm

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples

Supplier profile

PowerGridSource Imported Supplier Pool
主营:Transformers and Substation Equipment

View full profile >