PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
ZGS Series Outdoor Compact Pad-Mounted Combined Transformer, 63–1600 kVA
Pad Mounted Transformers

ZGS Series Outdoor Compact Pad-Mounted Combined T | RFQ Sourcing Details

Pad Mounted Transformers · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryPad Mounted Transformers
Unitset
NetworkAC 50 Hz, 6–10 kV
Core typeCore-type transformer
InstallationOutdoor or indoor
Winding typeSeparated winding transformer
CustomizationAvailable
Cooling methodOil-immersed
CategoryPad Mounted Transformers
AvailabilityInquiry required
Source date2026-07-21

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Pad Mounted Transformers. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

The ZGS Series is an American-type compact pad-mounted combined transformer designed as a complete power transformation and distribution unit. Its stated configuration integrates the transformer active part with switchgear, fuses, a tap changer, a low-voltage distribution assembly, and associated auxiliary equipment.

Available configuration options include metering, reactive-power compensation, and low-voltage feeder circuits. The unit is described for AC 50 Hz, 6–10 kV distribution networks, with rated capacities stated from 63 to 1,600 kVA. It uses an oil-immersed, core-type transformer with separated windings.

The enclosure is described as fully enclosed and fully insulated. Connection options are available for radial and ring-main systems, supporting system changeover arrangements. Installation may be indoors or outdoors.

The compact format is intended to reduce the required installation footprint and simplify site installation, operation, and maintenance. Listed use environments include industrial parks, residential developments, commercial centers, high-rise buildings, and temporary construction sites.

These are general stated applications;suitability for a particular network or site must be established from project-specific electrical and environmental requirements. Procurement confirmation is required before specification or ordering.

Buyers should verify the required primary and secondary voltages, exact rated capacity, vector group, impedance, tap range and tap-changing method, insulation level, protection scheme, fuse and switchgear ratings, low-voltage feeder arrangement, metering requirements, and reactive-power compensation configuration.

The source information contains inconsistent phase and capacity descriptors: it identifies the unit as three-phase in one attribute, references single-phase usage elsewhere, states 63–1,600 kVA in the overview, and lists 100–1,600 kVA in another attribute. Confirm the offered nameplate configuration in writing.

Also confirm enclosure rating, site altitude, ambient-temperature limits, cooling designation, permissible temperature rise, sound level, loss values, short-circuit withstand data, applicable product standards, required test reports, and whether listed management-system certifications apply to the manufacturing organization rather than the individual transformer.

The stated overall specification is 2200 × 1500 × 1800, but the unit and measurement basis are not identified;obtain an approved dimensional drawing before planning foundations, clearances, lifting, or transport.

ZGS | Applications and Buyer Notes

ZGS is organized as a sourcing-ready Pad Mounted Transformers reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time ques

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Pad Mounted TransformersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Network
AC 50 Hz, 6–10 kVBased on visible page data; confirm exact value in the RFQ.
Core type
Core-type transformerBased on visible page data; confirm exact value in the RFQ.
Installation
Outdoor or indoorBased on visible page data; confirm exact value in the RFQ.
Winding type
Separated winding transformerBased on visible page data; confirm exact value in the RFQ.
Customization
AvailableBased on visible page data; confirm exact value in the RFQ.
Cooling method
Oil-immersedBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryPad Mounted Transformers
Unitset
NetworkAC 50 Hz, 6–10 kV
Core typeCore-type transformer
InstallationOutdoor or indoor
Winding typeSeparated winding transformer
CustomizationAvailable
Cooling methodOil-immersed
Rated capacity63–1,600 kVA stated in the overview;another attribute states 100–1,600 kVA-confirm selected rating
Series / modelZGS
Transport packagingWooden package
Integrated equipmentTransformer active part, switchgear, fuses, tap changer, LV distribution assembly, and auxiliary equipment
Connection arrangementsRadial and ring-main options
Stated overall specification2200 × 1500 × 1800;unit and measurement basis not stated

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples

Supplier profile

PowerGridSource Imported Supplier Pool
主营:Pad Mounted Transformers

View full profile >