Product specs

CategoryTransformers and Substation Equipment
Unitset
ModelHMCXZ
PrintingSupported
WaveformSine wave;THD below 1.0%
ProtectionOver-current, over-voltage and flashover protection
Power supply220/380 V single-phase, 50 Hz;detailed tolerance stated as ±15% voltage and ±5% frequency
Product typeVariable-frequency AC resonant test system
CategoryTransformers And Substation Equipment
AvailabilityInquiry required
Source date2026-07-23

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Transformers And Substation Equipment. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

This 600 kV-class variable-frequency AC resonant test system is designed for high-voltage substation testing. Model HMCXZ is identified for testing cables, gas-insulated switchgear (GIS), transformers, gas-insulated transmission lines (GIL) and other test objects selected for the configured system.

The regular system configuration comprises a variable-frequency power source, excitation transformer, high-voltage reactor and capacitive voltage divider. During testing, the reactor and the capacitance of the test object form a series-resonant circuit.

The voltage divider measures resonant voltage and supplies an overvoltage-protection signal, while the excitation transformer couples the variable-frequency source to the resonant circuit.

Supported operating data include a 20–300 Hz output-frequency range, 0.1 Hz adjustment sensitivity and stated frequency instability below 0.05%. The specified output is a sine waveform with total harmonic distortion below 1.0%.

The system provides automatic and manual operating modes, digital control through a controller or computer, print support, and over-current, over-voltage and flashover protection. Its stated full-power continuous working time is 60 minutes. The listed power input is 220/380 V single-phase at 50 Hz.

A more detailed specification states 220/380 V ±15% and 50 Hz ±5%;the exact input arrangement should therefore be confirmed for the ordered configuration and installation site. Output voltage and capacity are configuration-dependent.

The product is presented as a 600 kV test system, while the technical description states that rated output voltage can be configured according to the test object, up to 1000 kV, and maximum capacity can reach 20,000 kVA. These maximum figures should not be interpreted as the rating of every supplied set.

A partial-discharge configuration is also described. It uses a partial-discharge variable-frequency power source, excitation transformer, PD-free high-voltage reactor and PD-free capacitive voltage divider. The stated partial-discharge level is below 5 pC, or below 10 pC when voltage reaches 600 kV or above.

Buyers should confirm whether this configuration is included and under which rated-voltage and test conditions those limits apply. Before procurement, define the test object, required test voltage, load capacitance, test duration and applicable test procedure.

Request a configuration schedule identifying every system component and its individual ratings. Also confirm calibration documentation, acceptance criteria, controls, protection settings, cable and accessory scope, transport package, installation requirements, training, commissioning and the governing warranty terms.

Customization and calibration support are stated as available, but their exact deliverables require written agreement.

600 | Applications and Buyer Notes

600 is organized as a sourcing-ready Transformers And Substation Equipment reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and l

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Transformers and Substation EquipmentBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Model
HMCXZBased on visible page data; confirm exact value in the RFQ.
Printing
SupportedBased on visible page data; confirm exact value in the RFQ.
Waveform
Sine wave;THD below 1.0%Based on visible page data; confirm exact value in the RFQ.
Protection
Over-current, over-voltage and flashover protectionBased on visible page data; confirm exact value in the RFQ.
Power supply
220/380 V single-phase, 50 Hz;detailed tolerance stated as ±15% voltage and ±5%Based on visible page data; confirm exact value in the RFQ.
Product type
Variable-frequency AC resonant test systemBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryTransformers and Substation Equipment
Unitset
ModelHMCXZ
PrintingSupported
WaveformSine wave;THD below 1.0%
ProtectionOver-current, over-voltage and flashover protection
Power supply220/380 V single-phase, 50 Hz;detailed tolerance stated as ±15% voltage and ±5% frequency
Product typeVariable-frequency AC resonant test system
Test objectsCable, GIS, transformer and GIL
CustomizationAvailable
Operating modesAutomatic and manual
Output frequency20–300 Hz
Frequency instabilityBelow 0.05%
Nominal product class600 kV
Partial-discharge levelStated below 5 pC;below 10 pC at 600 kV or above
Frequency adjustment sensitivity0.1 Hz
Configurable rated output voltageBased on the test object;stated maximum up to 1000 kV

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples

Supplier profile

PowerGridSource Imported Supplier Pool
主营:Transformers and Substation Equipment

View full profile >