PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
Ideal voltage conversion equipment for factory power system
Transformers And Substation Equipment

Ideal voltage conversion equipment for factory po | RFQ Sourcing Details

Transformers And Substation Equipment · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryTransformers and Substation Equipment
Unitset
3011 / 10.5 / 10 / 6.3 / 6 ±5 / ±2×2.5% 0.4 / 0.69 Yyn0 / Dyn /
50130 910 /
63150 1090 /
80180 1310 /
100200 1580 /
125240 1890 /
CategoryTransformers And Substation Equipment
AvailabilityInquiry required
Updated2026-05-30

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Transformers And Substation Equipment. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

. Overview Specification After Sales Service FAQ Overview . Model NO.

S11 Core Core-type Transformer Cooling Method Oil-immersed Type Transformer Winding Type Two-winding Transformer Certification ISO , ISO9001, CCC Usage Power Transformer Frequency Characteristics Power Frequency Shape of Core EI Brand VIBRANT Type Oil-Type Transport Package Wooden Crate Packaging Specification The dimensions vary according to different models Trademark VIBRANT Origin China HS Code Packaging & Delivery Package Size 1000.00cm * 1000.00cm * 1000.00cm Package Gross Weight 500.000kg The oil-immersed transformer The oil-immersed transformer is widely used in power distribution, industrial and civil power supply.

It adopts high-quality oriented silicon steel sheet and optimized winding structure, with low no-load loss, low noise and lower energy consumption. Reasonable oil circulation design ensures excellent heat dissipation and stable temperature rise.

Integral corrugated tank features high mechanical strength and good sealing performance to prevent oil leakage.

Specification Features: 1) Amount of local discharged: The apparent discharge amount is less than 80pC under 1.5 times of rated voltage;2) Noise: Products of 63MVA and below is lower than 58 dB (AN);3) Power loss: no-load loss is 30% lower than that of IEC standard;4) Reliability: All in-service products have no damages or oil leakage occurred;Application: 60 ~220 kV power system of power plant, substation, mining enterprise and etc.

Technologies: Design: relative developed software are adopted in Electromagnetic calculations, strength analysis, leakage magnetic distribution, its electro-dynamic force and electrical insulation.

Technical Specifications (Custom configurations available upon request.) RATED CAPACITY (kVA) HIGH VOLTAGE (kV) HV TAPPING RANGE (%) LOW VOLTAGE (kV) VECTOR GROUP SYMBOL NO-LOAD LOSS (W) LOAD LOSS (W) NO-LOAD CURRENT (%) SHORT-CIRCUIT IMPEDANCE (%) 30 11 / 10.5 / 10 / 6.3 / 6 ±5 / ±2×2.5% 0.4 / 0.69 Yyn0 / Dyn / / / / / / / / / / / / Manufacture: Core: 1.

Adopt high-permeability grain-oriented cold-rolled silicon steel sheets, cut by advanced German automatic shear line with burrs within 0.02mm. 2. Apply non-upper yoke lap joint and 45° full miter structure.

Laminated sheets are integrally bonded with epoxy resin for high rigidity and vertical precision, improving no-load performance and reducing noise. 3. Reinforced with bracing plates, fiber band binding, counter-pressure bolts and three-point fixing structure.

The internal unit can resist transportation vibration without displacement. Winding: 1. The HV coil adopts an interleaved-continuous structure to realize uniform impulse voltage distribution. All stays and pads are chamfered to ensure stable and reliable insulation performance. 2.

A zigzag oil guide structure is arranged inside windings for comprehensive cooling, which reduces temperature rise and hot spots and extends insulation service life.

Independent regulating windings for HV and MV balance ampere turns, reduce axial short-circuit electromagnetic force, and strengthen the transformer's sudden short-circuit withstand capability. 3. The winding features a radial zero-clearance design.

All components between the core, low-voltage paper sleeve and each winding are fully dried and closely assembled, ensuring excellent overall compactness and concentricity. Oil Tank and Accessories: 1.

The tank wall is integrally folded into a seamless corrugated structure with wide steel plates, cutting down welding seams and upgrading mechanical strength. The corrugated structure also optimizes heat dissipation and noise reduction.

Secondary circuit wiring ducts and control cabinets are made of stainless steel for a neat and aesthetic appearance. 2. All sealing surfaces are precision-machined and equipped with high-grade sealing materials. 3. Double sealing grooves are designed on the tank edge.

The outer sealing layer provides atmospheric and UV shielding to protect inner seals, effectively prolonging sealing life and improving equipment operational reliability. After Sales Service Standard Warranty: 12 months or 2,000 operating hours (whichever comes first).

Global Support: 24/7 technical assistance and spare parts supply. Training: On-site or remote operation/maintenance training. FA;load loss means winding copper loss under rated current. Our products adopt high-grade oriented silicon steel sheet to keep low loss and energy saving. Q:What is the short-circuit impedance?

A:It is a key parameter for anti-short circuit capability, normally 4% / 4.5% / 5% for distribution transformers. Q:What's the vector group? A:Standard types are Dyn11 and Yyn0;Dyn11 has better harmonic resistance and short-circuit performance. Q:Can the high voltage tapping range be customized?

A:Standard is ±5% or ±2×2.5%;customized tapping range is available. Q:What material is the transformer core and winding? A:Core: cold-rolled grain-oriented silicon steel sheet;Winding: high-purity oxygen-free copper wire. Q:Is the tank wall corrugated type?

A:Yes, integral folded corrugated tank, seamless welding, good heat dissipation and noise reduction. Q:How about the insulation and sealing performance? A:High-strength insulating material, double sealing grooves + UV-resistant outer seal, no oil leakage for long-term operation.

Q:What ambient temperature and altitude are suitable? A:Suitable for -25℃-40℃, altitude ≤1000m;special upgrade for high altitude / high temperature area. Q:Can it operate continuously at full load? A:Long-term full-load operation is supported;proper overload is allowed within a short time.

Q:What cooling method do you adopt? A:Standard ONAN (oil natural circulation, air natural cooling). Q:Will the internal structure be damaged during transportation? A:Reinforced fixing for iron yoke

Ideal | Applications and Buyer Notes

Ideal is organized as a sourcing-ready Transformers And Substation Equipment reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Transformers and Substation EquipmentBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
30
11 / 10.5 / 10 / 6.3 / 6 ±5 / ±2×2.5% 0.4 / 0.69 Yyn0 / Dyn /Based on visible page data; confirm exact value in the RFQ.
50
130 910 /Based on visible page data; confirm exact value in the RFQ.
63
150 1090 /Based on visible page data; confirm exact value in the RFQ.
80
180 1310 /Based on visible page data; confirm exact value in the RFQ.
100
200 1580 /Based on visible page data; confirm exact value in the RFQ.
125
240 1890 /Based on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryTransformers and Substation Equipment
Unitset
3011 / 10.5 / 10 / 6.3 / 6 ±5 / ±2×2.5% 0.4 / 0.69 Yyn0 / Dyn /
50130 910 /
63150 1090 /
80180 1310 /
100200 1580 /
125240 1890 /
160280 2310 /
200340 2730 /
250400 3200 /
315480 3830 /
400570 4520 /
500680 5410 /
CoreCore-type Transformer
TypeOil-Type
BrandVIBRANT
PhaseThree
Powerloss: no-load loss is 30% lower than that of IEC standard;4) Reliability: All in-service products have no damages or oil leakage occurred
UsagePower Transformer
OriginChina
voltagetapping range be customized? A:Standard is ±5% or ±2×2.5%;customized tapping range is available. Q:What
FrequencyCharacteristics
Model NO.S11
TrademarkVIBRANT
ApplicationPower, Electronic
US$1,000.001 Piece ( )
Package Size1000.00cm * 1000.00cm * 1000.00cm
Winding TypeTwo-winding Transformer
CertificationISO , ISO9001, CCC
CustomizationAvailable
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Shape of CoreEI
Shipping Cost.
SpecificationThe dimensions vary according to different models
Cooling MethodOil-immersed Type Transformer
Transport PackageWooden Crate Packaging
After Sales ServiceStandard
Package Gross Weight500.000kg
RATED CAPACITY (kVA)HIGH VOLTAGE-LOAD LOSS-LOAD CURRENT-CIRCUIT IMPEDANCE
Frequency CharacteristicsPower Frequency

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples