PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
SXBP Series Resonant AC Hipot Test System for Power Cables, GIS and Substation Equipment
Transformers And Substation Equipment

SXBP Series Resonant AC Hipot Test System for Pow | RFQ Sourcing Details

Transformers And Substation Equipment · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryTransformers and Substation Equipment
Unitset
Input PowerAC 380 V is listed in the basic information;the description also references 220 V or 380 V single-phase supply-confirm for the selected system
Package Size100 × 80 × 180 cm listed
CustomizationAvailable
Result OutputTest-result printing listed
Accuracy Grade0.5 listed
Equipment TypeSeries resonant AC hipot test system
CategoryTransformers And Substation Equipment
AvailabilityInquiry required
Source date2026-07-23

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Transformers And Substation Equipment. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

The SXBP is a configurable series resonant AC hipot test system intended for AC withstand testing of electrical equipment in substations rated from 10 kV through 500 kV or below.

Listed test objects include XLPE power cables, GIS, power transformers, generators, switchgear, circuit breakers, motors, insulators, bushings, power capacitors and CT/PT equipment. It is described for field, acceptance, preventive and maintenance testing.

The system uses modular reactors that can be arranged to suit different voltage and capacity requirements. Available configurations list a 20–300 Hz test-frequency range and include an AC power source, exciting transformer, reactors and a capacitive voltage divider.

Depending on the selected model, the listed power-source and exciting-transformer ratings range from 5 kW to 30 kW. The also identifies real-time screen display of test data, operating status and procedural steps, computer control, LCD display and printable test results.

Protection functions listed for the system include overcurrent, overvoltage, IPM and discharge protection. The reactors are described as dry-type epoxy-cast units with high mechanical strength, insulation capability and limited temperature rise at rated load.

The equipment is presented as portable for field operation, although package dimensions and gross weight indicate that transport and handling arrangements should be reviewed for the chosen configuration.

Configuration examples include SXBP-27/54/108-108, SXBP-54/108/216-216, SXBP-65/130/260-520, SXBP-45/90/135/180/270-270 and SXBP18/36/54. Published examples cover specific cable lengths and conductor sizes as well as GIS, transformer, circuit-breaker, busbar, insulator and switchgear test duties.

These examples should be treated as configuration references rather than universal capability statements.

Before procurement, the buyer should provide the exact test object, rated voltage, required test voltage, capacitance or cable conductor size and length, desired test duration, available site input supply, test location and applicable acceptance procedure.

Confirm the reactor quantity and connection, total system capacity, divider rating, accessories, control and printing functions, package breakdown, lifting requirements and final factory test documentation.

The available information gives inconsistent warranty terms-one section lists two years, while another states one year-so the warranty period and after-sales scope should be resolved in the purchase contract.

Input-power information should also be confirmed because the listing includes both AC 380 V and 220/380 V single-phase references.

SXBP | Applications and Buyer Notes

SXBP is organized as a sourcing-ready Transformers And Substation Equipment reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Transformers and Substation EquipmentBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Input Power
AC 380 V is listed in the basic information;the description also references 220Based on visible page data; confirm exact value in the RFQ.
Package Size
100 × 80 × 180 cm listedBased on visible page data; confirm exact value in the RFQ.
Customization
AvailableBased on visible page data; confirm exact value in the RFQ.
Result Output
Test-result printing listedBased on visible page data; confirm exact value in the RFQ.
Accuracy Grade
0.5 listedBased on visible page data; confirm exact value in the RFQ.
Equipment Type
Series resonant AC hipot test systemBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryTransformers and Substation Equipment
Unitset
Input PowerAC 380 V is listed in the basic information;the description also references 220 V or 380 V single-phase supply-confirm for the selected system
Package Size100 × 80 × 180 cm listed
CustomizationAvailable
Result OutputTest-result printing listed
Accuracy Grade0.5 listed
Equipment TypeSeries resonant AC hipot test system
Series / ModelSXBP series
Transport PackagePlywood case
Listed Test ObjectsXLPE cable, power transformer, generator, GIS, high-voltage switchgear, motor, insulator, bushing, power capacitor, circuit breaker, busbar and CT/PT
Package Gross Weight800 kg listed
Protection FunctionsOvercurrent, overvoltage, IPM and discharge protection
Common System ComponentsAC power source, exciting transformer, reactor modules and capacitive voltage divider
Substation Equipment RangeDescribed for equipment at 10 kV–500 kV or below

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples

Supplier profile

PowerGridSource Imported Supplier Pool
主营:Transformers and Substation Equipment

View full profile >