PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
Premium Quality Flame-Retardant Copper Wire with Mica Insulation
Grounding Cables

Premium Quality Flame-Retardant Copper Wire with | RFQ Sourcing Details

Grounding Cables · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryGrounding Cables
Unitset
SizeCustomization
TypeInsulated
powersystems that require high
OriginJiangsu, China
Side B2mm~16mm
Side a0.9mm~6mm
CategoryGrounding Cables
AvailabilityInquiry required
Updated2026-05-31

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Grounding Cables. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

. Overview Specification FAQ Overview . Model NO.

2.12*8.5 Application Generators, Transformers, and Other Equipment Conductor Material Copper Sheath Material Polyester Insulation Material Mica Tape Material Shape Flat Wire Range of Application Refractory Certification ISO9001, CE Product Name Mica Tape Wrapped Copper Flat Wire Keywords Film-Reinforced Mica-Insulated Wire Side a 0.9mm~6mm Side B 2mm~16mm Size Customization Material T2/Tu2 Insulation Layer Customization Core Function High Voltage and Corona Resistant Winding Wire Mechanical Performancev High Wear Resistance and Bending Durability OEM & ODM Custom Accept Transport Package Pallet or Customization Specification 2.12*8.5 Trademark SHENLONG Origin Jiangsu, China Production Capacity 10000 T/Year MICA TAPE WRAPPED COPPER FLAT WIRE Mica Tape Wrapped Copper Flat Wire is a high-performance winding wire designed for demanding high-voltage, high-temperature motor and transformer applications.

Using a copper flat conductor as the base, it is tightly wrapped with mica tape insulation, optionally reinforced with polyimide (PI) film and polyester (PET) film to deliver outstanding dielectric strength, corona resistance, and mechanical durability.

Compared with standard enameled round wire, this mica-insulated copper flat wire offers a higher slot fill factor, better heat dissipation, and significantly improved service life under inverter pulse voltages and harsh thermal conditions.

It is an ideal choice for EV drive motors, wind power generators, high-voltage transformers, industrial servo motors, rail transit traction motors, and aerospace power systems that require high voltage resistance, heat resistance above 200°C, corona resistance, and long-term reliability.

KEY FUNCTIONAL FEATURES HIGH-VOLTAGE & CORONA RESISTANCE Mica tape primary insulation withstands up to 800V pulse voltages and effectively prevents corona erosion under inverter-driven conditions, ensuring stable long-term operation in high-frequency PWM environments.

ULTRA-HIGH TEMPERATURE PERFORMANCE Operating range of 220°C–240°C continuous with short-term capability to 400°C, maintaining flexibility across extreme temperature variations and thermal cycling without degradation.

SUPERIOR MECHANICAL DURABILITY Composite PI/PET reinforcement provides excellent wear, tear, and abrasion resistance, eliminating mica brittleness and ensuring process-friendly performance during automated winding and insertion.

OIL & CHEMICAL RESISTANCE Proven compatibility with transformer oil, refrigeration fluids, and industrial solvents, while maintaining inherent flame-retardancy for enhanced safety in harsh environments.

OPTIMIZED SLOT FILL & CUSTOMIZATION Rectangular flat conductor geometry increases copper density and heat dissipation;full customization of size and insulation thickness available for OEM/ODM projects.

Specification Item Of Inspection Standard Test Result Appearance Glass Around The Cladding Should Be Smooth,Continuous,There Is No Physical Damage And Impurities Qualified Conductor Size A a ±0.03 mm a-0.01 mm B b ±0.07 mm b-0.02 mm R r±25% mm Pass Insulation Thickness mm mm Max Outside Thickness 2.68 × 9.10 mm 2.64 × 9.02 mm Tensile Strength / / Elangation ≥30 % 38% Spring Back Angle ≤4.5 degree 3.6 degree Rigidity / / Flexibility/Bending Bending 10A 10B In 180°,The Insulating Layer Should Not Be Cracking.

Qualified Adhesiveness Ins.Layer Not Loose And Crack. / D.C.Resistance At 20 ℃ ≤0. Ω/m 0.

Ω/m Resistivity ≤0.017241Ω ·mm²/m 0.016845 Ω ·mm²/m Breakdown Voltage (10A 10B Bending)≥7.5KV Aging/Thermal Shock Ins.Layer Not Crack / Test Result Qualified Remarks The Self-Adhesive Is Qualified, Bonding At 180 Degrees For 30 Minutes Structural Layer Material Core Function Pain Point Solved Inner. Layer(Primary.

Insulation) Mica. Tape High. Voltage&Corona. Resistance Solves. The. Problem. OfEasy. Breakdown. And. Aging. OfOrdinary. Insulation. Under. High. Voltage. Middle. Layer(Thermal. Reinforcement) Polyimide(PI) High-Temperature. Resistance&Toughness Solves. The. Brittleness. And. Powdering. Issues. OfMica;Enhances.

Thermal. Rating. Outer. Layer(Mechanical. Protection) Polyester(PET) Toughness&Cost. Efficiency Provides. Extra. Tear. Resistance. And. Aids. InBonding/Formation. Application Field Typical Equipment Core Problem Solved New. Energy EVDrive.

Motors High Voltage Resistance(Withstanding 800 V Pulse Voltage) Power&Energy Wind Turbines, Transformers Long Life(>20 Years),Weather Resistance Advanced Manufacturing Industrial. Robots,Servo. Motors Corona Resistance(Resisting Inverter Harmonics) Transportation High-Speed.

Trains,Subways Heat Resistance(>200°C),Anti-Vibration Aerospace Aircraft. Power. Systems Wide Temperature Range, Lightweight FA d the package before you pay the balance. Q2: What are the terms of packing?

A: Generally, we pack our goods in bundles or coils with rods or belts;we could also pack the goods according to the customers' requirements. Q3: Could you produce according to the samples? A: Yes, we can make customer-made products from your samples or technical drawings, and we can build the mold and fixtures.

Q4: How could you guarantee your products quality? A: Each piece of product is We could issue the warranty to the customer to guarantee the quality. Q5: What's your delivery time?

A: We offer flexible solutions: standard products are typically completed within one week, while special processing products generally take 7 to 15 days. Jiangyin Shenlong Electric Materials Co., Ltd.

Premium | Applications and Buyer Notes

Premium is organized as a sourcing-ready Grounding Cables reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time question

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Grounding CablesBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Size
CustomizationBased on visible page data; confirm exact value in the RFQ.
Type
InsulatedBased on visible page data; confirm exact value in the RFQ.
power
systems that require highBased on visible page data; confirm exact value in the RFQ.
Origin
Jiangsu, ChinaBased on visible page data; confirm exact value in the RFQ.
Side B
2mm~16mmBased on visible page data; confirm exact value in the RFQ.
Side a
0.9mm~6mmBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryGrounding Cables
Unitset
SizeCustomization
TypeInsulated
powersystems that require high
OriginJiangsu, China
Side B2mm~16mm
Side a0.9mm~6mm
RemarksThe Self-Adhesive Is Qualified, Bonding At 180 Degrees For 30 Minutes
KeywordsFilm-Reinforced Mica-Insulated Wire
MaterialT2/Tu2
Rigidity/ /
warrantyto the customer to guarantee the quality. Q5: What's your delivery time? A: We offer flexible solutions
AerospaceAircraftPowerSystems Wide Temperature Range, Lightweight
Model NO.2.12*8.5
NewEnergyEVDriveMotors High Voltage Resistance(Withstanding 800 V Pulse Voltage)
TrademarkSHENLONG
AppearanceGlass Around The Cladding Should Be Smooth,Continuous,There Is No Physical Damage And Impurities Qualified
ODM CustomAccept
ApplicationGenerators, Transformers, and Other Equipment
Test ResultQualified
AdhesivenessIns.Layer Not Loose And Crack. /
Power&EnergyWind Turbines, Transformers Long Life(>20 Years),Weather Resistance
CertificationISO9001, CE
CustomizationAvailable
Specification2.12*8.5
Conductor SizeA a ±0.03 mm a-0.01 mm
Conductor TypeSolid
Material ShapeFlat Wire
SpecificationsSelect Now
TransportationHigh-SpeedTrains,Subways Heat Resistance-Vibration
US$300 kg ( )
Sheath MaterialPolyester
Insulation LayerCustomization
OEM & ODM CustomAccept
Tensile Strength/ /
Breakdown Voltage(10A 10B Bending)≥7.5KV
Transport PackagePallet or Customization
Conductor MaterialCopper
Item Of InspectionStandard Test Result
Aging/Thermal ShockIns.Layer Not Crack /
Flexibility/BendingBending 10A 10B In 180°,The Insulating Layer Should Not Be Cracking. Qualified
Insulation MaterialMica Tape
Production Capacity10000 T/Year
Insulation Thicknessmm mm
Range of ApplicationRefractory
Max Outside Thickness2.68 × 9.10 mm 2.64 × 9.02 mm
Mechanical PerformancevHigh Wear Resistance and Bending Durability
InnerLayer(PrimaryInsulation)MicaTape HighVoltage&CoronaResistance SolvesTheProblemOfEasyBreakdownAndAgingOfOrdinaryInsulationUnderHighVoltage.
OuterLayer(MechanicalProtection)Polyester(PET) Toughness&CostEfficiency ProvidesExtraTearResistanceAndAidsInBonding/Formation.
MiddleLayer(ThermalReinforcement)Polyimide-TemperatureResistance&Toughness SolvesTheBrittlenessAndPowderingIssuesOfMica;EnhancesThermalRating.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

Related applications PowerGridSource related paths

Industrial Power Distribution

Renewable Integration and Storage

Related solutions PowerGridSource related paths

Energy Metering and Protection Upgrades

Medium Voltage Distribution Projects

PowerGridSource procurement phrases

PowerGridSource related product samples