Rubber Insulated Power Cable Yc Yz Yzw Ycw Cables Multi Core Rubber Cable Construction Conductor: Stranded bare copper flexible, fully annealed, Bare-copper.
Insulation: Ethylene Propylene Diene Monomer EPDM or EPR Color: Black,Orange, Blue, Red etc Products characteristics Temperature range: EPR insulated cables should not be higher than 65°C,EPT/EPDM insulated cables should not be higher than 90°C.
VOLTAGE RATING: 450/750V, 650/1100V Application ran ge: -Hard-hold and power supply device acc -Day and damp interiors, as well as for limited outdoor use acc -Light and sound technology Features • EPDM insulation provides outstanding cut, abrasion and slag resistance • Resistant to oil, chemicals, water, ozone, & solvents • Red, Orange, Blue,Black jacket • Other colors available upon request Type Nominal Section (mm²) Structurer of Conductor Core No./Dia.(mm) Insulation Thickness (mm) Jacket Thickness (mm) Overall Diameter (mm) Rated Voltage Max.
Conductor Resistance at 20ºC (Ω/KM) H07RN-F 1X1.5 30/ ±0.2 450/750V 13.3 1X2.5 49/ ±0.2 450/750V 7.98 1X4 56/ ±0.3 450/750V 4.95 1X6 84/ ±0.3 450/750V 3.3 2X1 32/ ±0.3 450/750V 19.5 2X1.5 30/ ±0.3 450/750V 13.3 2X2.5 49/ ±0.4 450/750V 7.98 2X4 56/ ±0.4 450/750V 4.95 2X6 84/ ±0.4 450/750V 3.3 3X1 32/ ±0.3 450/750V 19.5 3X1.5 30/ ±0.4 450/750V 13.3 3X2.5 49/ ±0.4 450/750V 7.98 3X4 56/ ±0.4 450/750V 4.95 3X6 84/ ±0.5 450/750V 3.3 4X1 32/ ±0.4 450/750V 19.5 4X1.5 30/ ±0.4 450/750V 13.3 4X2.5 49/ ±0.4 450/750V 7.98 4X4 56/ ±0.5 450/750V 4.95 4X6 84/ ±0.5 450/750V 3.3 5X1 32/ ±0.4 450/750V 19.5 5X1.5 30/ ±0.4 450/750V 13.3 5X2.5 49/ ±0.5 450/750V 7.98 5X4 56/ ±0.5 450/750V 4.95 5X6 84/ ±0.6 450/750V 3.3 Type Nominal Section (mm²) Structurer of Conductor Core No./Dia.(mm) Insulation Thickness (mm) Jacket Thickness (mm) Overall Diameter (mm) Rated Voltage Max.
Conductor Resistance at 20ºC (Ω/KM) H03RN-F 1X0.5 16/ X0.75 24/ H05RN-F 2X0.75 24/ X1 32/ X0.75 24/ X1 32/ Welding Cable Data Sheet Nominal Section (mm²) Structure of conductor Overall Diameter (mm) Max. Conductor Resistance at 20ºC Approx. Weight (KG/KM) Core No./Dia.(mm) Min. Max.
Ω/KM YH YHF 10 322/ / / / / / / / / /
Rubber | Applications and Buyer Notes
Rubber is organized as a sourcing-ready Power Cables reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time questions bef
Applications
- Initial shortlist building for related product or supplier options.
- Specification and application fit review before bulk purchasing.
- Category, keyword and detail-page comparison before sending an RFQ.
Key specifications
- Category
- Power CablesBased on visible page data; confirm exact value in the RFQ.
- Unit
- setBased on visible page data; confirm exact value in the RFQ.
- VOLTAGE
- RATING: 450/750V, 650/1100VBased on visible page data; confirm exact value in the RFQ.
- Application
- ran ge:-Hard-hold andBased on visible page data; confirm exact value in the RFQ.
Buyer tips
- State quantity range and split-delivery needs before price comparison.
- Add certification, material or inspection standards when they affect acceptance.
- For time-sensitive projects, include target arrival date and destination.
- For special applications, describe operating condition, installation environment and duty cycle.
FAQ
What should buyers confirm first?
Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.
Can buyers inquire when specs are incomplete?
Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.
How should this listing be evaluated?
Check title, category, specifications and related keywords against the actual sourcing requirement.
Source mix: ugc
Key specifications
Product sourcing keywords
These terms come from the title, visible copy and specifications, and link into matching aggregate pages.
Continue from this detail page into sourcing structure
These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.
This URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 100kva 10kv Dry Type Transformer For Solar Power Systems 100kva And Solar Power SystemsThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 10kv Epoxy Resin Indoor Electric Single Phase Potential Transformer PtThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 10kv Power Supply Ring Main Unit Cable Accessories Ceramic Metal Silicone Rubber Epoxy Resin BushingThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 10p10 500 5a Split Core Ct Current TransformerThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 11kv 12kv 20kv 24kv Electrical Power Transmission Medium Voltage Air Insulated SwitchgearThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 11kv 12kv Medium Voltage Distribution Air Insulated SwitchgearThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 11kv 12kv Medium Voltage Sis Solid Insulation Compact Modular SwitchgearThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 150kva 20kv Dry Type Transformer With Low Loss Ce Low Loss And CeThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 23kv Oil Filled Ansi Standard Power Transformer Bay O Net B O N Inline Link Auto Electrical ThermaThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cables Busbar And Accessories categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Meters And Protection Devices categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Switchgear And Breakers categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Transformers And Substation Equipment categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
PowerGridSource related sourcing paths
Cables, Busbar and Accessories
PowerGridSource procurement phrases
PowerGridSource related product samples
Measure the power cable of different sections, different media of various materials, Coaxial cable, Street light cables ...
Cables, Busbar and Accessories Portable Live Cable Fault Identifier - Cable Fault Identifier and Underground Cable DetectorPortable Live Cable Fault Identifier Product overview I. GENERAL : power on cable identifier, also known as cable identi...
Cables, Busbar and Accessories Underground Living Cable Fault Identifier - Cable Fault Identifier and Underground Cable DetectorUnderground Living Cable Fault Identifier Product overview I. GENERAL : power on cable identifier, also known as cable i...
Cables, Busbar and Accessories 132kv 11.5kv 25mvaOutdoor,dust and water proof-phase,two-pole,vertical break
Cables, Busbar and Accessories Dry Air Generator for Transformers Air Dryer for Transformer - Dry Air Generator and Air Drying EquiFUOOTECH DAG-100 Transformer Dry Air Generator for transformer is mainly used to quickly and effectively provide dry air...
Transformers and Substation Equipment 6-Phase Relay Protection Test Equipment with Current Injectional Method for Substation MaintanenceDJB-426 6 Phase Relay Test Kit-199 "microcomputer relay protection test device technology", list