PowerGridSourceSwitchgear, transformers, breakers, metering devices, and power distribution components for global buyers.
Transformer Loss Tangent Tan Delta Test Set 10kv 12kv Automatic Tan Delta and Capacitance Anti-Inter
Harmonic Filters

Transformer Loss Tangent Tan Delta Test Set 10kv | RFQ Sourcing Details

Harmonic Filters · Quote on request

This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.

Quote on request

Product specs

CategoryHarmonic Filters
Unitset
After-sales ServiceLife Time Support
Calibration ReportFactory Report or The Third Party Report
Capacitance RangeInternal Hv: 3PF~60000PF/10kv 60PF~1μf/0.5kv
CertificateCE
DisplayLCD
External Hv3PF-1.5μf/10kv 60PF-30μf/0
CategoryHarmonic Filters
AvailabilityInquiry required
Updated2026-05-26

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Harmonic Filters. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

transformer loss tangent tan delta test set 10kv 12kv automatic tan delta and capacitance anti-interference dielectric loss dissipation power factor tester I.

Summary Tan Delta Test Set is a basic method in insulation test and effectively detect damp, degradation and partial defect of insulation of electrical equipment. This method is widely used in electric manufacturing, electric equipment installation, connection and preventive test.

Measurement on dielectric loss of transformer, mutual inductor, reactor, capacitor, bushing and arrester is the most basic method to test their insulation property.**** fully-automatic anti-interference dielectric loss tester breaks through the traditional bridge testing method and adopts variable frequency power technology, single chip and modernized electrical technology to carry out automatic frequency shift, analog-to-digital conversion and data computing.

It features strong anti-interference capacity, high test speed, high precision, automatic digitization and easy operation. It adopts high-power switching power supply, which outputs 45. Hz and 55. Hz pure sine wave and automatically increase the voltage to a maximum value 10 KV. It can filter 50.

Hz interference automatically, and Tan Delta Test Set is applicable to the site test of substation and other places with large electromagnetic interference.

This methods is extensively applied in dielectric loss measurement of transformer, mutual inductor, reactor, bushing, capacitor, arrester and others equipments in power industry. II.

Technical indicators Accuracy: Cx: ±(reading×1%+1pF) tgδ: ±(reading×1%+0.00040) Anti-interference: Variable frequency anti-interference, the above accuracy can be reached under 200% interference.

Capacitance range: Internal HV: 3pF~60000pF/10kV 60pF~1μF/0.5kV External HV: 3pF~1.5μF/10kV 60pF~30μF/0.5kV Resolution: Maximum 0.001pF, 4 valid figures. tgδ range:unlimited, 0.001% resolution, automatic identification for capacitance , inductance and resistance of three tested articles.

Test current range: 10μA~1A Internal HV: Set voltage range: 0.5~10kV Maximum output current: 200mA Buck-bust method: continuous stepless regulation Test frequency: 45, 50, 55 single frequency 45/55. Hz automatic dual variable frequency Frequency accuracy: ±0.01.

Hz External HV: In case of UST, maximum test current is 1A, and power frequency or variable frequency is 40-70. Hz In ca

Transformer | Applications and Buyer Notes

Transformer is organized as a sourcing-ready Harmonic Filters reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time ques

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Harmonic FiltersBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
After-sales Service
Life Time SupportBased on visible page data; confirm exact value in the RFQ.
Calibration Report
Factory Report or The Third Party ReportBased on visible page data; confirm exact value in the RFQ.
Capacitance Range
Internal Hv: 3PF~60000PF/10kv 60PF~1μf/0.5kvBased on visible page data; confirm exact value in the RFQ.
Certificate
CEBased on visible page data; confirm exact value in the RFQ.
Display
LCDBased on visible page data; confirm exact value in the RFQ.
External Hv
3PF-1.5μf/10kv 60PF-30μf/0Based on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryHarmonic Filters
Unitset
After-sales ServiceLife Time Support
Calibration ReportFactory Report or The Third Party Report
Capacitance RangeInternal Hv: 3PF~60000PF/10kv 60PF~1μf/0.5kv
CertificateCE
DisplayLCD
External Hv3PF-1.5μf/10kv 60PF-30μf/0
Frequency Input50Hz or 60Hz
FunctionCan Be Customzied
Funtion 2for Transformer Tan Delat Test and CVT Ratio Test
Maximum Output Current200mA
Model Input220V or 120V
Model NO.HM5006
OriginHubei, China(Mainland)
Power Source180V-270VAC, 50Hz/60Hz+-1%
ResolutionMaximum 0.001PF, 4 Valid Figures.
Specification460mm*360mm*350mm.
Test Current Range10μa-1A
Test MethodGst, Ust, CVT Ratio
Tgδ RangeUnlimited, 0.001% Resolution
The Max Output10kv, 12kv, 15kv or Higher
TrademarkHMDQ
Transport PackageWooden Box with Foam Inside
TypeTransformer Tester
Warranty1 Year or Extended
Weight28kg

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples