Product specs

CategoryTransformers and Substation Equipment
Unitset
ModelHZXD-II
Voltage range0.000 V to ±71.00 V;2 ranges
A/D conversionSuccessive approximation
Voltage accuracy±0.2%
Temperature range10.0°C to 60.0°C
Measured functionsBattery internal resistance, DC voltage, and temperature
CategoryTransformers And Substation Equipment
AvailabilityInquiry required
Source date2026-07-20

Buyer's Digest

Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Transformers And Substation Equipment. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.

Original product description

The HZXD-II is a portable rechargeable-battery analyzer designed to measure battery internal resistance, terminal voltage, and temperature. It is intended for battery production, installation, equipment production, and maintenance work involving lead-acid and lithium batteries.

The instrument may also provide reference measurements of electrolytic-capacitor equivalent series resistance. Internal resistance is measured using a 1 k. Hz AC four-terminal method, which is designed to reduce the influence of , terminals, and battery electrodes.

The stated internal-resistance range is 0.000 mΩ to 3.100 Ω, with 1 µΩ maximum resolution and ±0.5% stated accuracy. DC voltage measurement covers 0.000 V to ±71.00 V, with 1 mV resolution and ±0.2% stated accuracy. Temperature measurement covers -10.0°C to 60.0°C, with 0.1°C resolution and ±1.0°C stated accuracy.

For inspection and recordkeeping, the analyzer provides manual and automatic hold-and-storage functions, preset PASS/WARNING/FAIL threshold judgments, internal memory greater than 256 MB, a USB interface for storing and uploading data, and Bluetooth connectivity for supported smart devices.

Results are shown on a 3.5-inch, 320 × 240 color LCD. The display updates five times per second, the stated response time is 200 ms, and a measurement takes approxima age charging alert, and configurable automatic shutdown after approxima The specified operating environment is -10°C to 40°C at no more than 80% RH.

Procurement note: buyers should confirm the exact probe set, temperature sensor, USB accessories, Bluetooth software or app compatibility, supported export and printing formats, calibration documentation, and all items included in the quoted package.

The source information contains inconsistent references to AC/DC discharging and separate AC power specifications, while the detailed parameters identify this unit as an internal-resistance, voltage, and temperature analyzer with a DC-only measurement input.

Confirm the ordered configuration, maximum permitted connections, and whether any discharge function is actually included before purchase. Buyers should also confirm current warranty terms, customization scope, lead time, packaging, and service arrangements in the final order documentation.

HZXD-II | Applications and Buyer Notes

HZXD-II is organized as a sourcing-ready Transformers And Substation Equipment reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements a

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Transformers and Substation EquipmentBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Model
HZXD-IIBased on visible page data; confirm exact value in the RFQ.
Voltage range
0.000 V to ±71.00 V;2 rangesBased on visible page data; confirm exact value in the RFQ.
A/D conversion
Successive approximationBased on visible page data; confirm exact value in the RFQ.
Voltage accuracy
±0.2%Based on visible page data; confirm exact value in the RFQ.
Temperature range
10.0°C to 60.0°CBased on visible page data; confirm exact value in the RFQ.
Measured functions
Battery internal resistance, DC voltage, and temperatureBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Key specifications

CategoryTransformers and Substation Equipment
Unitset
ModelHZXD-II
Voltage range0.000 V to ±71.00 V;2 ranges
A/D conversionSuccessive approximation
Voltage accuracy±0.2%
Temperature range10.0°C to 60.0°C
Measured functionsBattery internal resistance, DC voltage, and temperature
Temperature sensorNTC, 10 kΩ at 26°C
Voltage resolution1 mV
Measurement current2.0 mA to 200 mA, depending on range
Battery types statedRechargeable lead-acid and lithium batteries
Temperature accuracy±1.0°C
Maximum input voltageDC 70 V between positive and negative measurement terminals;AC input not allowed
Temperature resolution0.1°C
Internal resistance range0.000 mΩ to 3.100 Ω;4 ranges
Internal resistance accuracy±0.5%
Resistance measurement method1 kHz AC four-terminal method;open-circuit terminal voltage 3 V maximum
Internal resistance resolution1 µΩ

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Continue from this detail page into sourcing structure

These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.

PowerGridSource related sourcing paths

PowerGridSource procurement phrases

PowerGridSource related product samples

Supplier profile

PowerGridSource Imported Supplier Pool
主营:Transformers and Substation Equipment

View full profile >