SL13-M-500 500 kVA 13.2 kV Oil-Immersed Pad-Mount | RFQ Sourcing Details
Pad Mounted Transformers · Quote on request
This is a product procurement detail page: check specs, images, category context and related sourcing paths before sending an RFQ.
Product specs
Buyer's Digest
Use this page as a product-first sourcing checkpoint before sending an RFQ. Category: Pad Mounted Transformers. Confirm application fit, capacity, materials, destination, lead time and compliance requirements before comparing suppliers.
Original product description
The SL13-M-500 is a 500 kVA oil-immersed, core-type distribution transformer offered for pad-mounted power-distribution projects. The stated electrical ratings are 13.2 kV on the high-voltage side and 400 V on the low-voltage side.
The listed construction includes aluminum windings, multi-winding configuration, and ONAN cooling, meaning oil-natural and air-natural circulation.
For the S13-M-500 configuration, the supplied technical table lists a high-voltage tapping range of ±2 × 2.5%, a 0.48 kW no-load loss, load-loss values of 5.41/5.15 kW, and 4% impedance. Dyn11 and Yyn0 vector groups appear in the shared model table, but the selected vector group for a purchased unit must be confirmed.
IEC 60076 is the stated transformer standard, and customization is available. Important procurement note: the source information is inconsistent about the nominal voltage class and phase configuration.
The product heading refers to 20 kV, while the model-specific basic information identifies 13.2 kV high voltage and 400 V low voltage. It also references both three-phase application information and single-phase usage.
Buyers should therefore treat 500 kVA, model SL13-M-500, 13.2 kV, and 400 V as the listed configuration while requiring an approved datasheet and drawings to establish the final electrical design.
Before purchase, confirm the required primary and secondary voltages, phase count, frequency, vector group, tap arrangement, insulation class, applicable standard edition, loss tolerances, impedance tolerance, and terminal configuration.
Also request confirmation of the pad-mounted enclosure arrangement, cable-entry layout, grounding provisions, protective accessories, oil specification, environmental conditions, installation altitude, and required routine or type tests.
Dimensions should be established from approved drawings rather than inferred from shipping information. The listed warranty is 12 months or 2,000 operating hours, whichever occurs first.
Buyers should confirm the warranty start point, exclusions, claim procedure, documentation package, inspection requirements, final packing method, delivery schedule, and availability of project-specific technical support in the purchase contract.
SL13-M-500 | Applications and Buyer Notes
SL13-M-500 is organized as a sourcing-ready Pad Mounted Transformers reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-ti
Applications
- Initial shortlist building for related product or supplier options.
- Specification and application fit review before bulk purchasing.
- Category, keyword and detail-page comparison before sending an RFQ.
Key specifications
- Category
- Pad Mounted TransformersBased on visible page data; confirm exact value in the RFQ.
- Unit
- setBased on visible page data; confirm exact value in the RFQ.
- Model
- SL13-M-500Based on visible page data; confirm exact value in the RFQ.
- Impedance
- 4%Based on visible page data; confirm exact value in the RFQ.
- Load loss
- 5.41/5.15 kWBased on visible page data; confirm exact value in the RFQ.
- Low voltage
- 400 VBased on visible page data; confirm exact value in the RFQ.
- Rated power
- 500 kVABased on visible page data; confirm exact value in the RFQ.
- High voltage
- 13.2 kVBased on visible page data; confirm exact value in the RFQ.
Buyer tips
- State quantity range and split-delivery needs before price comparison.
- Add certification, material or inspection standards when they affect acceptance.
- For time-sensitive projects, include target arrival date and destination.
- For special applications, describe operating condition, installation environment and duty cycle.
FAQ
What should buyers confirm first?
Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.
Can buyers inquire when specs are incomplete?
Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.
How should this listing be evaluated?
Check title, category, specifications and related keywords against the actual sourcing requirement.
Source mix: ugc
Key specifications
Product sourcing keywords
These terms come from the title, visible copy and specifications, and link into matching aggregate pages.
Continue from this detail page into sourcing structure
These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.
This URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Procurement sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 100 315 Kva Three Phase Copper Wound Oil Immersed Distribution TransformerThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cables Busbar And Accessories categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Meters And Protection Devices categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Switchgear And Breakers categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Transformers And Substation Equipment categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Ip65 Switchgear Panels sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path CompanyThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 11kv Distribution Transformers sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Electrical Equipment Exporters sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 100kva 10kv Cast Resin Dry Type Transformer Ul Certified 10kv Cast Resin And Ul CertifiedThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 100kva 10kv Dry Type Transformer For Solar Power Systems 100kva And Solar Power SystemsThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 10kv Power Supply Ring Main Unit Cable Accessories Ceramic Metal Silicone Rubber Epoxy Resin BushingThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
PowerGridSource related sourcing paths
Transformers and Substation Equipment
PowerGridSource procurement phrases
PowerGridSource related product samples
DJB-426 6 Phase Relay Test Kit-199 "microcomputer relay protection test device technology", list
Transformers and Substation Equipment 66kv 35kv 20kv 11kv Combined Transformer Substation Package CompactIntroduction: The needs of the wind power plant developed a special combination of a series of wind power substation, th...
Transformers and Substation Equipment 30kVA 50kVA 63kVA 80kVA 100kVA 10kv 33kv Zgs American Prefabricated Compact Substation - SubstationThis product is to absorb the latest foreign advanced technology, combined with the actual situation of domestic researc...
Transformers and Substation Equipment American Type Outdoor Usage Combined Power Transformer Box Substation - Substation and Electrical EqThis product is to absorb the latest foreign advanced technology, combined with the actual situation of domestic researc...
Transformers and Substation Equipment Substation Cable Junction Plug Terminal Joint Electrical Equipment for Power Substation Price - SubsThis product is to absorb the latest foreign advanced technology, combined with the actual situation of domestic researc...
Transformers and Substation Equipment 132kv 11.5kv 25mvaOutdoor,dust and water proof-phase,two-pole,vertical break