Original product description
This KETE pad-mounted substation is described as a compact outdoor power-distribution unit combining a transformer, high-voltage switchgear, and low-voltage outgoing cable equipment in a sealed metal enclosure.
It is listed as an oil-immersed, two-winding, core-type transformer with a vertical outline and silicon-steel core material. The winding material is specified as copper or aluminum, so the required conductor must be stated in the purchase specification.
Configuration options shown in the supplied data include three-phase service, 50 or 60 Hz frequency, 4.16–37 kV high voltage, and customizable low voltage. Listed low-voltage values in the technical table include 0.24, 0.277, 0.347, 0.48, and 0.6 kV, with other values noted as available.
Connection options include Dyn11, Yyn0, or other specified arrangements. Both loop-feed and radial-feed configurations are listed. Available tap ranges are stated as ±5% or ±2 × 2.5%, using a five-step voltage regulator. The technical table covers nominal capacities from 75 to 3,750 kVA.
It lists impedance values of 4.0–6.0%, while no-load and on-load losses vary by capacity. Because this product is customized, buyers should request the exact loss schedule and guaranteed values for the selected rating rather than treating the complete table as applying to every configuration.
The stated operating envelope includes altitudes up to 1,000 m and ambient temperatures from -25°C to +40°C. Daily average relative humidity is listed as no more than 95%, with a monthly average no more than 90%.
The specified installation environment should be free from severe vibration, corrosive gases, explosive media, and heavy dust pollution. Listed protection-class options are IP20 and IP54, and insulation-class options are F and H. The required combination should be confirmed for the installation site.
IEC 60076 is identified as the applicable standard. The listing also names ISO 9001 and CCC, while separate product text refers to additional certification systems.
Buyers should obtain current, model-specific certificates and verify that their selected transformer, switchgear, voltage class, and destination-market configuration are covered. Certification statements should not be assumed to apply uniformly to every customized version.
Procurement questions to confirm before ordering include the required kVA rating;primary and secondary voltages;phase and frequency;Dyn11, Yyn0, or another vector group;radial- or loop-feed arrangement;copper or aluminum windings;tap range;impedance;guaranteed losses;enclosure protection class;insulation class;installation altitude and climate;cable entry and termination details;protection devices;foundation interface;overall dimensions and weight;required drawings;inspection and test documentation;and applicable destination-market approvals.
KETE | Applications and Buyer Notes
KETE is organized as a sourcing-ready Transformers And Substation Equipment reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and
Applications
- Initial shortlist building for related product or supplier options.
- Specification and application fit review before bulk purchasing.
- Category, keyword and detail-page comparison before sending an RFQ.
Key specifications
- Category
- Transformers and Substation EquipmentBased on visible page data; confirm exact value in the RFQ.
- Unit
- setBased on visible page data; confirm exact value in the RFQ.
- Phase
- Three phaseBased on visible page data; confirm exact value in the RFQ.
- Standard
- IEC 60076Based on visible page data; confirm exact value in the RFQ.
- Core type
- Core-type transformerBased on visible page data; confirm exact value in the RFQ.
- Frequency
- 50/60 HzBased on visible page data; confirm exact value in the RFQ.
- Impedance
- 4.0–6.0% listed in the technical tableBased on visible page data; confirm exact value in the RFQ.
- Tap range
- ±5% or ±2 × 2.5%Based on visible page data; confirm exact value in the RFQ.
Buyer tips
- State quantity range and split-delivery needs before price comparison.
- Add certification, material or inspection standards when they affect acceptance.
- For time-sensitive projects, include target arrival date and destination.
- For special applications, describe operating condition, installation environment and duty cycle.
FAQ
What should buyers confirm first?
Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.
Can buyers inquire when specs are incomplete?
Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.
How should this listing be evaluated?
Check title, category, specifications and related keywords against the actual sourcing requirement.
Source mix: ugc
Key specifications
Product sourcing keywords
These terms come from the title, visible copy and specifications, and link into matching aggregate pages.
Continue from this detail page into sourcing structure
These links connect the detail page back to category hubs, procurement aggregates and knowledge pages so new inventory is not isolated.
This URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 1 0 Sqmm Dual Core Copper Flexible House Wiring Cable At Best Price In BengaluruThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Procurement sourcing pathThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Cables Busbar And Accessories categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Meters And Protection Devices categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Switchgear And Breakers categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path Transformers And Substation Equipment categoryThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path CompanyThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 100kva 10kv Cast Resin Dry Type Transformer Ul Certified 10kv Cast Resin And Ul CertifiedThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 100kva 10kv Dry Type Transformer For Solar Power Systems 100kva And Solar Power SystemsThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 10kv Power Supply Ring Main Unit Cable Accessories Ceramic Metal Silicone Rubber Epoxy Resin BushingThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 11kv 12kv 20kv 24kv Electrical Power Transmission Medium Voltage Air Insulated SwitchgearThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 11kv 12kv Medium Voltage Sis Solid Insulation Compact Modular SwitchgearThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
Internal sourcing path 126kv 1250a Dry Resin Impregnated Fiber Transformer BushingThis URL was refreshed but still has no Googlebot evidence, so it is promoted into shared internal links for crawl discovery.
PowerGridSource related sourcing paths
Medium Voltage Distribution Projects
PowerGridSource procurement phrases
PowerGridSource related product samples
DJB-426 6 Phase Relay Test Kit-199 "microcomputer relay protection test device technology", list
Transformers and Substation Equipment 66kv 35kv 20kv 11kv Combined Transformer Substation Package CompactIntroduction: The needs of the wind power plant developed a special combination of a series of wind power substation, th...
Transformers and Substation Equipment 30kVA 50kVA 63kVA 80kVA 100kVA 10kv 33kv Zgs American Prefabricated Compact Substation - SubstationThis product is to absorb the latest foreign advanced technology, combined with the actual situation of domestic researc...
Transformers and Substation Equipment American Type Outdoor Usage Combined Power Transformer Box Substation - Substation and Electrical EqThis product is to absorb the latest foreign advanced technology, combined with the actual situation of domestic researc...
Transformers and Substation Equipment Substation Cable Junction Plug Terminal Joint Electrical Equipment for Power Substation Price - SubsThis product is to absorb the latest foreign advanced technology, combined with the actual situation of domestic researc...
Transformers and Substation Equipment 132kv 11.5kv 25mvaOutdoor,dust and water proof-phase,two-pole,vertical break